English
Turn Adjuster
2
Too Deep
If nails are driven too shallow, turn the adjuster to the
deep side.
Turn Adjuster
2
Too Shallow
3 Stop turning the adjuster when a suitable position is
reached for a nailing test.
4 Connect the air hose.
ALWAYS WEAR EYE PROTECTION.
Perform a nailing test.
5 DISCONNECT AIR HOSE FROM NAILER.
6 Choose a suitable position for the adjuster.
CHANGING THE EXHAUST DIRECTION
● When changing the exhaust direction, be
sure to remove your fi nger from the trigger
and disconnect the air hose from the nailer.
The direction of the exhaust vent can be changed by
turning the top cover.
Top Cover
Exhaust
Vent
18
Flush
Flush
WARNING
USING THE NOSE CAP
● When attaching or detaching the nose cap,
be sure to remove your fi nger from the trigger
and disconnect the air hose from the nailer.
If you like to protect the surface of workpiece against
scratches or markings made by the push lever, attach the
accessory nose cap to the push lever.
1 DISCONNECT AIR HOSE FROM NAILER.
2 Put the nose cap to the toe of the push lever.
3 The nose cap is marked to indicate the exit point of
the nail, making alignment easier.
4 When not using the nose cap, secure in the storage
compartment located on the reverse side of the
magazine.
2
Push Lever
Nose Cap
Magazine
Nose Cap
NOTE:
● The nose cap may reduce nailing depth due to its
thickness. Re-adjustment of nailing depth is required.
WARNING
1
Disconnect
air hose