English
(1) Intermittent operation (Trigger fi re)
Use the SINGLE SEQUENTIAL ACTUATION
MECHANISM setting.
● For intermittent operation, set the change
rod as shown in the fi gure below. (i.e.
Set to SINGLE SEQUENTIAL ACTUATION
MECHANISM.)
● To avoid double fi ring or accidental fi ring due
to recoil.
1) Set the switching device to SINGLE
SEQUENTIAL ACTUATION MECHANISM.
2) Pull the trigger rapidly and fi rmly.
1 Follow the steps below to set up the SINGLE
SEQUENTIAL ACTUATION MECHANISM (as
shown in the diagrams that follow).
● Disconnect the air hose and remove all nails.
● Do not depress the push lever.
● Do not apply any unnecessary pressure or
use any tools to move the switch.
● Do not press the change stopper for any
other purpose other than to switch between
SINGLE
SEQUENTIAL
CONTACT ACTUATION.
1) If the lock pin is left, skip 2) through 3) and
proceed from 4).
2) Press the bottom of the trigger and open the
change stopper.
3) Grasp the change rod between two fi ngers
and slide it downwards.
(Sets the SINGLE SEQUENTIAL ACTUATION
MECHANISM)
4) Make sure that the change rod is in its proper
position as shown in the diagram.
(If not, the tool may be set in the CONTACT
ACTUATION MECHANISM.)
2 Position the nail outlet on the workpiece with
fi nger off the trigger.
3 Depress the push lever fi rmly until it is completely
depressed.
4 Pull the trigger to drive a nail.
5 Remove fi nger from the trigger.
To continue nailing in a separate location, move the
nailer along the wood, repeating steps 2 – 5 as
required.
16
WARNING
WARNING
ACTUATION
3
Push Lever
● A nail will fi re each time the trigger is
depressed as long as the push lever remains
depressed.
and
(2) Continuous operation (Push lever fi re)
Using CONTACT ACTUATION MECHANISM
● To avoid double fi ring or accidental fi ring due
to recoil.
1) Do not press the nailer against the wood
with excessive force.
2) Separate the nailer from the wood as it
recoils after nailing.
● If the hook is affi xed, do not operate with
CONTACT ACTUATION MECHANISM.
1 Follow the steps below to set up the CONTACT
ACTUATION MECHANISM (as shown in the
diagrams that follow).
● Disconnect the air hose and remove all nails.
● Do not depress the push lever.
● Do not apply any unnecessary pressure or
use any tools to move the switch.
Position of
Change Rod
1
4
Trigger
WARNING
WARNING
WARNING