Télécharger Imprimer la page

Metabo HPT NT 65A5 Manuel D'instructions Et De Sécurité page 12

Cloueur de finition

Publicité

Les langues disponibles

Les langues disponibles

English
(1) DISCONNECT AIR HOSE FROM NAILER.
REMOVE ALL NAILS FROM NAILER.
□ ALL SCREWS MUST BE TIGHTENED.
If any screws are loose, tighten them.
□ THE PUSH LEVER AND TRIGGER MUST MOVE
SMOOTHLY.
Trigger
Push lever
(2) REMOVE ALL NAILS FROM NAILER.
DO NOT push or rest Push Lever against any surface.
DO NOT FORCE OR USE TOOLS TO OPERATE
SWITCH.
Select SINGLE SEQUENTIAL ACTUATION MODE
according to the following steps.
1 Open the change stopper by pushing the bottom of
trigger.
2 Grasp the change rod between two fi ngers (one on
each side of the trigger) and slide it down (Single
Sequential Actuation Mode.)
3 Confi rm that the change stopper has completely
returned to original position inside the trigger.
(SINGLE SEQUENTIAL ACTUATION MECHANISM).
Grasp The
Change Rod 2
1
Push The Change stopper
12
(3) Adjust the air pressure to 70 psi (4.9 bar 5 kgf/cm
(4) Remove the fi nger from the trigger and press the
Do not connect
air hose
(5) Separate the push lever from the wood.
(6) First pull the Trigger.
Connect the air hose.
□ THE NAILER MUST NOT LEAK AIR.
push lever against the wood.
□ THE NAILER MUST NOT OPERATE.
Depress
push lever
Next, point the nailer downward, pull the trigger and
then wait in that position for 5 seconds or longer.
□ THE NAILER MUST NOT OPERATE.
Pull trigger
Next, depress the Push Lever against the wood.
□ THE NAILER MUST NOT OPERATE.
3
Position of
Change Rod
).
2
Do not pull
trigger

Publicité

loading