Installation
This luminaire can be suspended from a suspension
bar by means of A6, A25 or A30 hook clamps; it
can also be mounted on a stand (these accessories
are available as options).
Avoid installing the luminaire near inflammable
matters. Minimum distance between luminaire
and inflammable matters is indicated on the
identification plate.
Stay within the maximum tilt angles allowed
(indicated on the identification plate).
In accordance with safety regulations, ALWAYS
attach a safety cable to the luminaire yoke.
In accordance with safety regulations, it is
an obligation to use a wire mesh lens safety
guard to prevent accidental fall of glass pieces
resulting from lens breaking.
Remark:
The weight of the accessories shall not be more
than 25% of the weight of the luminair.
Wire Mesh Safety Guard
This wire mesh safety guard is supplied with the
luminaire. It must always stay within the filter frame
cassette to prevent the fall of glass pieces in case
of lens breaking.
Insert this wire mesh safety guard into the slot
closest to the lens.
Filter Frame
A filter frame is supplied with the luminaire. Insert
colour gel filter into this filter frame. Then insert the
filter frame into the filter frame cassette and close
the access door.
4-leaf Barndoor
Open the filter frame cassette access door. Insert
the barndoor ring into the slot farest from the lens.
Then close the access door.
Lamping
ALWAYS unplug luminaire power supply cable
before re-lamping.
Open the access door to the lamp.
Refer to identification plate and to following
paragraph for the type of lamp to use. For optimal
lamp performance, please refer to manufacturer's
notice.
Plug the lamp into the lampholder (GY 9,5), fixed
on the lamp carrier.
Lamp must be changed if damaged or distorted
by heat.
Type of lamp to use
lampholder
light centre height (HCL) : 46.5 mm
wattage
voltage

Electrical Connection

This luminaire is designed for operation at a
maximum voltage of 220 V - 240 V.
It is delivered with a cable HO7-RNF 3 x 1.5 mm
length, equipped with a EEC 22 at the luminaire site.
In use, take care to move away the cable from
the hot parts of the luminaire.
For your own safety, check that the earth wire
(yellow-green) is ALWAYS connected to earth.
Plug the cable into the socket at luminaire's lower
part. Secure the power plug by means of the stirrup.
A 56 C
A 57 F
A 59 Z
: GY 9.5
: 300 W, 500 W or 650 W
: 220 V - 240 V
2 m
2