12.3 Procedure
Step 1: Check the system
In case of malfunctions, first check the system or the system part where the
u
product is installed. Check the following items:
• Are all connections connected to the product?
• Does the operating voltage comply with the requirements? See
cal
data.
• Does the operating pressure comply with the requirements? See
nical
data.
Step 2: Check the product
1. Make sure the system or system part is not under pressure or voltage (acci-
dent prevention, material protection).
2. Check the product based on the fault patterns described below. See
g 12.4 Malfunction
types.
3. Perform troubleshooting using the information under "Remedy".
4. Put the system or system part and product back into operation.
If you are unable to eliminate the malfunction as described under "Remedy": Dis-
assemble the product and send to the specified address. See back cover.
DANGER! Do not dismantle the product (accident prevention). Do not carry out
any unauthorized repair attempts (accident prevention, material protection).
12.4 Malfunction types
Malfunction
Possible cause
Pressure level or flow level is
• Filter contaminated
not reached or slowly de-
• Selected filter size
creases.
13 Technical data
This section contains an excerpt of the most important technical data. Further
technical data can be found in the online catalog.
General
Specifications
Ambient temperature
-40 °C ... 70 °C
Weight
Series 645
0.340 kg / 0.75 lbs
Series 646
0.513 kg / 1.13 lbs
Series 647
1.199 kg / 2.64 lbs
Assembly
Specifications
Mounting orien-
Vertical
tation
Pneumatics
Specifications
Medium temper-
-40 °C ... 70 °C
ature
Flow rates: Particulate filter
Thread
Micron rating
[microns]
1/8"
5
25
40
1/4"
5
25
40
3/8"
5
25
40
1/2"
5
25
40
AVENTICS™ 645, 646, 647 | 555858-001 | English
Remedy
• Clean or replace filter
• Select larger filter
too small
Flow rate [L/min ANR (SCFM)]
645
646
885 (31.2)
-
920 (32.5)
-
980 (34.6)
-
1250 (44.1)
2020 (70.8)
1410 (49.6)
2250 (89.3)
1550 (54.7)
2640 (92.4)
-
2190 (76.5)
-
3390 (118.7)
-
3870 (135.5)
-
2290 (80.2)
-
3700 (129.5)
-
4370 (153.0)
Micron rating
Thread
3/4"
1"
g 13. Techni-
g 13. Tech-
Flow rates: Coalescing filter
Micron rating
Thread
1/8"
1/4"
3/8"
1/2"
3/4"
1"
Standards and directives complied with
EN 61373, Cat. 1, Class B
ISO 9227
EN 45545, HL3
14 Accessories
Information on spare parts and accessories can be found in the online catalog.
Description
Particulate filter elements
Coalescing filter elements
Particulate filter repair kit (filter retainer, head
647
baffle, lower end cap, and lower baffle)
-
-
Metal bowl
-
-
-
Manual stainless steel condensate drain
-
Drain plug assembly
-
-
-
3850 (136.0)
4600 (162.4)
5550 (196.0)
Flow rate [L/min ANR (SCFM)]
[microns]
5
-
25
-
40
-
5
-
25
-
40
-
Flow rate [L/min ANR (SCFM)]
[microns]
645
0.3
430 (15.3)
0.01
310 (10.9)
0.3
480 (17.0)
0.01
350 (12.4)
0.3
-
0.01
-
0.3
-
0.01
-
0.3
-
0.01
-
0.3
-
0.01
-
For all versions
Shock and vibration
Corrosion resistance (salt spray test: 250 hrs)
Railway applications – Fire protection on railway vehicles
Series
5 microns
645
646
647
25 microns
645
646
647
40 microns
645
646
647
0.3 microns
645
646
647
0.01 microns
645
646
647
645
646
647
645
646
647
645 / 646 / 647
645 / 646 / 647
-
4000 (141.3)
-
4700 (166.0)
-
6500 (229.5)
-
4250 (150.1)
-
5000 (176.6)
-
6950 (245.5)
646
647
-
-
-
-
800 (28.0)
-
710 (25.0)
-
820 (28.6)
-
790 (27.5)
-
870 (30.5)
2300 (81.2)
830 (29.1)
1800 (63.6)
-
2550 (90.0)
-
1900 (67.1)
-
2600 (91.8)
-
2250 (79.5)
Item no.
M651AE434063001
M652AE433582001
M653AE439490001
M651AE434063002
M652AE433582002
M653AE439490002
M651AE434063003
M652AE433582003
M653AE439490003
M645AE552498001
M646AE552499001
M647AE552500001
M645AE552498002
M646AE552499002
M647AE552500002
M651AY570170001
M652AY506833001
M653AY514105001
M651AU434133002
M652AU440511002
M653AU507439002
M699AQ440512003
M699AQ440512001
20