EASY TECH D F
Index
Description
b09
DHW demand type selection
Flowmeter timing (b02=1)
Flowmeter timing (b02=2)
b10
No effect on adjustment (b02=3)
No effect on adjustment (b02=4)
DHW mode activation flow rate (b02=1)
DHW mode activation flow rate (b02=2)
b11
No effect on adjustment (b02=3)
No effect on adjustment (b02=4)
b12
Enable Auto-Settings procedure
Notes:
1.Parameters with more than one description vary their function and/or range in relation to the setting of the parameter
given in brackets.
2.Parameters with more than one description are reset to the default value if the parameter given in brackets is modified.
To exit the configuration Menu press the DHW buttons together for 10 seconds, or exiting occurs automatically after 2
minutes.
Service menu
The card Service Menu is accessed by pressing the Reset button for 20 seconds. 4 submenus are available: press the
Heating buttons to select, in increasing or decreasing order, "tS", "In", "Hi" or "rE". "tS" means Transparent Parameters
Menu, "In" means Information Menu, "Hi" means History Menu: after selecting the submenu, press the Reset button
again to access it; "rE" means History Menu Reset: see description.
"tS" - Transparent Parameters Menu
21 parameters, indicated by the letter "P" are available, which are also modifiable from Remote Timer Control.
Press the Heating buttons to scroll the list of parameters in increasing or decreasing order. Press the DHW buttons to
view or modify the value of a parameter: the change will be automatically saved.
Table 10
Index
Description
P01
Ignition ramp Offset
P02
Heating ramp
P03
Heating standby time
P04
Heating Post-Circulation
P05
Heating user max. setpoint
P06
Max. output in heating
EN
Range
0 = Flow switch
1 = Flowmeter (190 imp/l)
2 = Flowmeter (450 imp/l)
3 = Flowmeter (700 imp/l)
0 = Deactivated
1 ÷ 10=seconds
0=Deactivated
1-10=seconds
--
--
10 ÷ 100 L/min/10
10 ÷ 100 L/min/10
--
--
0 = Disabled
1 = Enabled
Range to use
9 ÷ 19
1-20°C/minute
0-10 minutes
0-20 minutes
31-85°C
0-100%
cod. 3542B960 - Rev. 01 - 04/2023
Parameter
2
1
15
0
EASY TECH D F
15
5
2
6
80
100
59