EASY TECH D F
Table 7 - Accessories
PIPE
BEND
Ø 80
PIPE SECTION
TEE
TERMINAL
FLUE
REDUCTION
PIPE
Ø 100
BEND
TERMINAL
PIPE
BEND
Ø 60
REDUCTION
TERMINAL
EN
0.5 m M/F
1 m M/F
2 m M/F
45° F/F
45° M/F
90° F/F
90° M/F
90° M/F + Test point
with test point
for condensate drain
for condensate drain
air, wall
fumes, wall with antiwind
Split air/fumes 80/80
Fume outlet only Ø80
from Ø80 to Ø100
from Ø100 to Ø80
1 m M/F
45° M/F
90° M/F
air, wall
fumes, wall with antiwind
1 m M/F
90° M/F
80 - 60
fumes, wall
ATTENTION: CONSIDER THE HIGH PRESSURE LOSSES OF Ø60 ACCESSORIES; USE THEM
ONLY IF NECESSARY AND AT THE LAST FUME EXHAUST SECTION.
cod. 3542B960 - Rev. 01 - 04/2023
Air
inlet
1KWMA38A
0.5
1KWMA83A
1.0
1KWMA06K
2.0
1KWMA01K
1.9
1KWMA65A
1.9
1KWMA02K
2.0
1KWMA82A
1.5
1KWMA70U
1.5
1KWMA16U
0.2
1KWMA55U
-
1KWMA05K
-
1KWMA85A
2.0
1KWMA86A
-
1KWMA84U
-
1KWMA83U +
-
1KWMA86U
1KWMA03U
0.0
1.5
1KWMA08K
0.4
1KWMA03K
0.6
1KWMA04K
0.8
1KWMA14K
1.5
1KWMA29K
-
010028X0
-
010029X0
-
010030X0
-
1KWMA90A
-
Losses in m
eq
Fume exhaust
Vertical
Horizontal
0.5
1.0
1.0
2.0
2.0
4.0
2.9
2.9
3.0
2.5
2.5
0.2
3.0
7.0
-
5.0
12.0
4.0
0.0
3.0
0.4
0.8
1.0
1.3
-
3.0
2.0
6.0
6.0
8.0
7.0
53