NOTE: For areas with uneven floors, a No. 566P3
Adjustable Rear Leg Extension Kit is available as
optional equipment at extra cost.
8. Verify that unit does not rock.
6
1. Washer Base
2. Locknut
3. Leveling Leg
4. Rubber Cup
5. 13 mm [1/2 inch] Clearance Between Washers
6. Level
Figure 9
Plug In the Washer
Electrical Requirements
120 Volt, 60 Hertz with 3-Prong Earth/Ground Plug
NOTE: The wiring diagram is located in the control
hood.
To reduce the risk of fire, electrical shock or person-
al injury, all wiring and grounding MUST conform
with the latest edition of the Canadian Electrical
Code, Parts I and II, and such local regulations as
might apply. It is the customer's responsibility to
have the wiring and fuses checked by a qualified
electrician to make sure the laundry room has ade-
quate electrical power to operate the washer.
When plugging in the washer:
•
DO NOT overload circuits.
•
DO NOT use an extension cord.
•
DO NOT use an adapter.
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
All manuals and user guides at all-guides.com
1
4
5
TLW2100N_SVG
WARNING
•
DO NOT operate other appliances on the same circuit. Use
separately fused 15 Amp circuits.
The washer is designed to be operated on a separate branch, po-
larized, three-wire, effective earth/ground, 120 Volt, 60 Hertz,
AC (alternating current), circuit protected by a 15 ampere fuse,
equivalent fusetron or circuit breaker.
The three-prong earth/ground plug on the power cord should be
plugged directly into a polarized three-slot effective earth/ground
2
receptacle rated 110/120 Volts AC (alternating current) 15 Amps.
Refer to Figure 10 to determine correct polarity of the wall recep-
tacle.
Standard 120 Volt, 60 Hertz 3-Wire Effective Earth/
Ground Circuit
3
1
8
1. L1
2. Earth/Ground
3. Neutral Side
4. Round Earth/Ground Prong
5. Neutral
6. 0 V.A.C.
7. 120 ± 12 V.A.C.
8. 120 ± 12 V.A.C.
W110
15
2
3
6
7
4
DRY2022N_SVG
Figure 10
Part No. 202630R2
Installation