Adjustable parameters
switchable de-energized
48 V
switchable energized
24 V
Ignition lead
5 V to 48 V
Waiting time to be ready for measurement
20 °C
0°C
-25°C
-40°C
10
Adjustable parameters
Some instrument parameters may be set differently by a Dräger Interlock
service centre due to legal regulations in different countries or individually
during installation. The descriptions of these Instructions for Use are related to
the basic version.
Table of essential adjustable parameters:
Parameter
Operation
Display of test result
Breath test volume
Limit value (initial test)
Restart period
Data storage
Data storage
Service
32
All manuals and user guides at all-guides.com
Interlock 5x00
Interlock 7x00
7 s
25 s
<5 s
<60 s
<60 s
<115 s
<110 s
Basic version
Test passed/Test failed
1.0 L
0.30‰ or 0.20‰
30 minutes
on
Parameter
Calibration interval
Possible to start engine after the end
of the service interval
Retest
Retests (whilst the vehicle is in use)
2 s
Lockouts
Duration of the instrument lockout
after a breath alcohol test with a high
concentration
Access code
Access code (for overriding the instru-
ment for a limited time period)
11
Order list
Name and description
Dräger Interlock 5x00
Alcohol interlock (handset and control unit) for
installation in motor vehicles, 12 V to 24 V,
mouthpieces (3 pieces) and mounting accesso-
ries
Dräger Interlock 7x00
Alcohol interlock (handset and control unit) for
installation in motor vehicles, 12 V to 24 V,
mouthpieces (3 pieces) and mounting accesso-
ries
Mouthpieces (5 pieces)
Mouthpieces (50 pieces)
Mouthpieces (300 pieces)
Instructions for use
Basic version
365 days
Yes
No
5 minutes
Yes
Order no.
83 22 550
83 22 570
83 26 550
83 27 627
83 22 597
|
®
Dräger Interlock