Saving, Retrieving And Deleting Results; Cleaning And Storing The Instrument - Beurer medical BM 16 Mode D'emploi

Masquer les pouces Voir aussi pour BM 16:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 23
sure as well as the value above which your blood pressure is
classified as dangerous.
The bar graph in the display and the scale on the unit indicate
the range of the blood pressure which has been recorded.
If the values for systolic and diastolic pressure are in two dif­
ferent ranges (e.g. systolic in the high­normal range and dias­
tolic pressure in the normal range) the graphic classification on
the unit indicates the higher range (high­normal in the example
described).
Table for classification of blood pressure values (unit of
measurement mmHg) for adults:
Range
Systolic
Hypotonia
< 105
( degraded blood
pressure)
Normal range
105 – 119 60 – 79
Pre­hypertensive
120 – 139 80 – 89
blood pressure
range*
High blood pres­
140 – 159 90 – 99
sure ­ degree
High blood pres­
≥ 160
sure ­ degree
(*) Blood pressure range that might transfer to high blood pressure
Diastolic Action
< 60
Self check
Self check
Check with doctor
Consult your
doctor
≥ 100
Consult your
doctor
Adapted from JNC 2003

6. Saving, retrieving and deleting results

The computer automatically saves the blood pressure readings
of the last 50 measurements. When the 50 memory locations
are exceeded, the current oldest value is deleted.
You can display the memory as follows:
• Press the user selection button
zone, and press the M key to switch from memory to mem­
ory with sequence numbers.
• The saved measured values are continuously stored.
• Press the On/Off switch
• If you forget to switch off the computer, it will switch off auto­
matically after 1 minute.
Press the user selection button
zone, then press and hold the M key for approximately 5­sec­
onds to clear the data in the pre­designated memory zone.
The data in both memory zones – zone 1 and zone 2 may be
erased if any of the batteries is removed.

7. Cleaning and storing the instrument

• Clean your device and cuff carefully only with a slightly mois­
tened cloth.
• Do not use detergents or solvents.
• On no account must you immerse the computer in water,
otherwise liquid can enter it and cause demage.
• When storing the device, make sure that no heavy objects
are placed on top of it. Remove the batteries. The cuff tube
should not have any sharp kinks.