GB
6.2.1
Manual mode
A
B
C
G
The operator must set appropriate values for the wire feed speed and welding
voltage.
6.2.2
QSett t t t mode
A
E
B
D
C
G
In QSett mode the appropriate welding voltage is automatically set by the machine.
QSett monitors the welding arc and continuously adjusts the voltage to maintain the
optimal setting.
Calibration
The first time you use QSett mode, and when you change welding wire material or
shielding gas, you need to allow QSett to calibrate. This is done by making a test
C200ie
All manuals and user guides at all-guides.com
F
I
H
F
I
H
- - 63 - -
A -- welding voltage
B -- welding current
C -- wire feed speed
F -- voltage setting knob
G -- Manual / QSett mode button
H -- dynamics setting button
I -- wire feed speed setting knob
A -- welding voltage
B -- welding current
C -- wire feed speed
D -- workpiece thickness
E -- QSett value
F -- QSett value setting knob
G -- Manual / QSett mode button
H -- material selection /
dynamics setting button
I -- plate thickness setting
knob