TECHNICAL DATA SPECIFICATIONS
Fuel
Firing rate
Effective output
Voltage (single phase)
Absorbed electrical power
Motor (rated)
Capacitor
Pump pressure
Primary control
Ignition transformer
BURNER AND MOUNTING FLANGE DIMENSIONS
Model F10
A
Inches
10 5/16
mm
262
E1: 10-inch long (254mm) tubes are also available.
BURNER COMPONENTS IDENTIFICATION
1
2
3
4
20101909
6
BURNER COMPONENTS
1 Lockout indicator lamp and reset but-
ton
2 Primary control
3 Primary control sub-base
4 Pump pressure regulator adjustment
screw
5 Capillary tube
6 Motor
7 Hydraulic jack
8 Capacitor
9 Hydraulic air shutter
2902451
No. 2 Fuel Oil
1.45 to 2.95 GPH 4.7 to 9.5 kg/h
203,000 to 413,000 BTU/h - 59.5 to 121 kW
51,160 to 104,130 kcal/h
120V 60Hz (+ 10% - 15%)
230 Watts
3250 rpm Run Current 2.2 AMP
12.5 Microfarads 260V
100 to 200 psi
RIELLO 530 SE/C
8kV 16mA
B
C
D
12
8 1/32
3 15/16
305
204
100
11
7
8
9
10
10 Air adjustment fixing screws
11 End cone
12 Adjustable collar
13 Turbulotor adjustment screw
14 Air tube cover
15 Mounting flange with gasket
16 Vacuum gauge connection port
17 Inlet fuel line port
18 Return fuel line port
19 Pressure gauge and bleeder port
20 Coil
E
F
5
10 7/16
127
265
12
13
15
5
17
18
2
E
E1
D7428
G
H
I
1 1/4
1/4
7/16
32
6
11
14
20
16
19
G
5 1 / 2 " - 140 mm
7 1 / 2 " - 190 mm
8 15 / 32 " - 215 mm
GB
B
F
L
2 3/16
56
D6000