Introduction
This Quick Start Guide contains instructions on the operation of the product
and relevant safety information.
Detailed information on the product can be found in the operating instructions
which are available for download on our website at www.renfert.com/p915.
Enter the following item number: 29300050
Symbols
In the instructions for use and on the unit itself you will find these symbols with the following meanings:
Danger
This indicates a direct risk of injury. Consult accompanying documents!
Electrical current
This indicates a risk of hazard due to an electrical current.
Attention
Disregarding this warning may result in damage to equipment.
Note
This provides the operator with useful information to improve and ease use.
The device complies with the requirements of the applicable EU directives.
This product complies with the relevant UK legislation.
See UKCA Declaration of Conformity in the Internet under www.renfert.com.
The device is subject to the EU directive 2002/96/EG (WEEE directive).
Other symbols are explained as they occur.
Safety
Intended Use
The product is intended for indoor use for the extraction of dry, non-explosive dust particles. The ambient
temperature must be between 5 - 40 °C.
This device is intended solely for commercial use in a dental laboratory.
The intended use also includes compliance with the instructions specified by the manufacturer concerning
operation, servicing and maintenance.
The extraction unit can be used in combination with a SILENT flow sensor within the scope of measures
to protect against exposure to dust *) as defined by the German ordinance on hazardous substances
("GefStoffV") / respective employers' liability insurance association.
For this purpose, the information on low-dust disposal of the extracted material (chapter "Emptying the
dust drawer") and on low-dust replacement of the fine filter (chapter "Replacing the fine filter") in particular
must be observed.
In doing so, both the instructions for use of the extraction unit as well as those of the SILENT flow
sensor must be observed.
*) Note for customers in Germany: A validated and recognized dust protection measure in accordance with testing
principle GS-IFA-M20 (issued by the German Institute for Work and Health IFA) shall only be deemed to have
been provided when all components, i.e. the flow rate monitoring unit such as the SILENT flow sensor, the ex-
traction unit, and the detection unit, are validated and recognized.
In the case of multi-workbench extraction units and the use of Y-junctions or extractor switches, every suction
channel / every suction point must be fitted with a flow rate monitoring unit.
Hazard and Warning Information
General Information
► If the device is not used in compliance with the supplied instructions, the safety of the device can
no longer be guaranteed.
► Only operate the device under supervision.
► The mains plug must be easily accessible.
- 1 -
en