Scope of Delivery
1
Silent TS2
1
Operating instructions
1
Quick reference card
1
Dust bag (ready for us in the dust drawer)
1
Compressed air tube (sealed)
2
Pinch valves with suction port
1
Connection set
2
Shockproof plug (only for 2930-0050)
1
4 m Suction Hose
4
PVC end bushings
Setting Up
Unpacking
⇒ Check the delivery for completeness (refer to the "Scope of Delivery" section).
Setup
If the device is to be installed in a cabinet, an opening for the exhaust air with the following dimensions
must be provided, in addition to the openings for the suction hoses:
• Circular opening:
• Rectangular opening:
Installing the Pinch Valves
⇒ Push the suction pipe (16) onto the suction support on the
extractor and hang the holder (20) onto the holder screws.
⇒ Connect the compressed air tubes to the pinch valves:
- Push the compressed air tube onto the pipe connection
in the pinch valve as far as it will go. There will be a slight
resistance to overcome when attaching.
Connection
⇒ Connect to the compressed air supply system, using a con-
nection kit if necessary (17, Fig. 1).
Observe the minimal / maximum connection pressure, see technical data!
Compressed air should be clean and dry (without condensed water). Wet compressed air can
damage the unit.
⇒ Shorten the suction pipes for both extraction points to the required length with a knife.
⇒ Screw the PVC end bushings onto the suction pipes (left handed thread).
Caution: risk of injury!
When shortening the suction pipe please ensure to cut at a right angle.
⇒ Fit suction hose (18) in intake socket (15) and connect to suction point.
Long suction hoses, tight bends and kinks will considerably reduce the extraction force at the
extraction point.
⇒ Electrical appliances can be connected to the coupler sockets (9, Fig. 1) at the back of the unit. Check
the connections are correct - coupler socket (A, B) - suction hose / pinch valve (A, B).
When connecting electrical appliances to the extraction unit, please ensure that the power con-
sumption of all devices connected to the unit power outlet does not exceed the total maximum
power for connected equipment (see "tech. Data").
Before connecting the device, ensure that the voltage information on the identification plate corre-
sponds with your local power supply.
⇒ Insert the mains cable into the plug socket.
Min. 120 mm diameters.
Min. 170 x 65 mm.
- 3 -