8 Maintenance
62
All manuals and user guides at all-guides.com
8.2.4
Replacing the spray water cartridge
Required accessories
● Spray water cartridge
● Midwest
If the spray water cartridge leaks or is clogged.
A
B
1. Remove the quick coupling from the supply hose.
2. Remove the sealing washer (B).
3. Click the control ring into the maximum water flow. The spray water
C
4. Remove the spray water cartridge.
5. Spray oil lightly onto the new spray water cartridge.
6. Insert the new spray water cartridge.
7. Note the position of the bulging side (C) when fitting the sealing
Operating Instructions Midwest Stylus
®
Plus Aerosol Spray
cartridge (A) can be replaced only in this position.
washer.
®
®