Télécharger Imprimer la page

Delba DB-870-10CZ Mode D'emploi page 77

Publicité

Les langues disponibles

Les langues disponibles

5 After ignition the power
is off 15min later.
6 orange and lazy fire,
piled pellet, carbon on the
glass
7 The fire put out and
power is off
automatically.
8 The blower still works
after the stove is cool and
fuel feed stops.
Pellet feeder unit is off, or
pellet is too little.
30˚C temperature switch
breaks or the connection
wires of switch loose.
Pressure Switch is broken
in the stove
Lack of air intake for
burning.
The hopper is empty.
No fuel feed.
The fuel feed is too little.
low temperature switch
(30˚C) is wrong. Set
temperature is
reached
The low temperature
switch (30˚C) is broken.
77
Check the pellet feeder unit and
restart.
Check the connection wires or
change the 30˚C temperature switch.
Replace or repair the device
Clean the block in gate bar.
Check the door and window glass
gasket sealed or not.
Check the air intake pipe and venting
pipe blocked or not and clean it.
Change to the big diameter pipes if
pipes are too long to affect
combustion.
Adjust the combustion fan's speed up
Call the dealer to reset the program
Put fuel into the hopper. refer to (2)
Lower the speed of combustion fan
Cool the stove at least 1 hour then
operate again or change the low
temperature switch (30˚C).
"ECO" its normal, waiting, after the
temperature is blow set on, it will
automatically switch on again
Change this switch.

Publicité