6. Error List
*******************************************************
It means fire put out automatically during the
operation, when the exhaust gas temperature is
below 40-45degree.
Such as: 1. There has no fuel at hopper.
2. Auger motor is broken and stop feeding the fuel.
It means there is earthquake during the
operation time. or You tilt the stove. Only for
the Japan version
It means that there are some problems with vacuum
Switch.
Such as door has not been closed properly;
Combustion fan's speed cannot Speed up;
There is some leakage about the stove or
exhaust pipe is blocked and so on.
During the operation, the stove is interrupted by
electronic cut.
If check everything is fine, you can press
!! ATTENTION!!
It means Igniter failure at the beginning.
Such as: 1. there have clinkers in fire pot.
2.
The fire pot has not put right.
3.
The switch which is located beside the
combustion fan to test the exhaust gas
temperature sensor, is broken,
4.
The igniter is broken
Problem for the temperature sensor.
Unplug or broken or water temperature is too high
(This function only for the pellet stove with hot
water)
It means that the high temperature sensor ,
which is located below the hopper, has some
problem, such as: 1. the switch is broken, 2. The
temperature is too high that the stove runs not
properly
It means you need to clean the stoves.
to delete the Error code
!! ATTENTION!!