3. No feeding after 20 seconds of starting.
There are three stages for the feeding process.
One is during the several minutes, feeding is constantly. "Feeding" is showing on the LCD
display
Two is the following couple minutes, the feeding light is off.: "Light" showing on the Display
The last stage is that feeding Every several seconds all the time after previous stages.
A. For the first stage
(during first several
minutes)
B. For the second stage
C. Regarding to the last
stage
4. Feeding not properly A.
too much wood pellet and
cannot burned in time
B. The fire is off due to
little wood pellet can be
burned
Feed unit is blocked.
There is the problem
about the connection
between motor and auger
No fuel in the hopper.
It is normal
Feed unit is blocked.
There is the problem
about the connection
between motor and auger
No fuel in the hopper.
The level of feeding speed
is too high
The level of feeding speed
is too low
76
Check the auger is blocked or not.
Check the fasten screw between
auger and motor loose or not.
Or the auger might jump out
Fill the fuel into the hopper.
Please be patient
Check the auger is blocked or not.
Check the fasten screw between
auger and motor loose or not.
Or the auger might jump out
Fill the fuel into the hopper.
Adjust the combustion fan's speed up
or Feeding quantity
Adjust the combustion fan's speed
Down or feeding quantity

Publicité

loading

Produits Connexes pour Delba DB-870-10CZ

Ce manuel est également adapté pour:

Db-870-10brDb-870-10bm