7. Display and control unit state
7.1 Normal functioning:
 
Standby - Gate closed or after the switch on of the control unit

Opening phase

Closing phase

Gate closed by user during opening

Gate closed by user during closing

Gate stopped by an external event (photocells, stop)

Gate opened without automatic reclosing

Gate opened in partial opening position without automatic reclosing

Gate opened waiting for auto reclosing, last 10 seconds the dash will be replaced by the countdown

Gate opened in partial opening position waiting for auto reclosing, last 10 seconds the dash will be replaced by the countdown
..
During the normal functioning and out from any menu, the pression of the DOWN[-] button lets you see the number of cycles
done, you will see units with dots on the bottom of display and thousand without dot, another pression of DOWN[-] or MENU

button let you to leave the cycles visualization

Visualized during the learning of transmitters

Visualized when memorized a new transmitter or at the and of a reset

Visualized when memorized a key of a transmitter already memorized

Visualized when a trasmitter is erased
Visualized during the learnign of strokes to indicate that the control unit is opening the gate and waiting for the command of

opening mechanical stop
Visualized during the learning of strokes to indicate that the control unit is clkosign the gate and waiting for the command of

closing mechanical stop

Visualized during the learning of strokes if there is an intervention of safety devices

Visualized when the control unit waits a transmitter signal, during the function of viewing of the memory

Visualized when the transmitter is not stored on the memory, during the function of viewing of the memory location.

Visualized when the control unit exits from the function of viewing of the memory location for inactivity.

Visualized during the first coupling with the Bluetooth device.

Visualized when the control unit is connected to a Bluetooth device

Visualized when Bluetooth device is disconnecting from the control unit.
7.2 Errors:

Impact sensor intervention

Safety edge intervention

Limit switches error (both opening and closing electrical limit switches busy in the same time)

Malfunctioning of photocells

Thermical intervention to preserve the control unit

Memory error

Full memory

Memory error during functions viewing memory location or cancellation of a single transmitter
The visualization of an error on the display persist until another command is given