6. Menu
Entering the menu:
To enter the base menu settings keep pressed the MENU button for at least one second
To enter the advanced menu settings keep pressed the MENU button for at least five seconds
Navigation into the menu:
It is possible to move from an entry to another one using UP[+] e DOWN[-] buttons,
To change a parameter keep pressed the MENU button for at least 1 second until the parameter begins blinking,
so release the key.
Use UP[+] and DOWN[-] buttons to change the parameter
At the end keep pressed MENU for al least 1 second until the parameter stops blinking to save the change.
A quick pressure of the menu key is enough to leave a menu
6.1 Base settings menu:
MENU

Auto reclosing time (0 = disabled)

Auto reclosing time after transit(0 = disabled)

Obstacle sensitivity (0 = disabled 100 = maximum sensitivity)

Motor torque (running torque)
Slowing down mode

0 = normal
1 = fast with more torque
Step by step configuration
0 = normal (OP-ST-CL-ST-OP-ST...)
1 = alternated STOP (OP-ST-CL-OP-ST-CL...)

2 = alternated (OP-CL-OP-CL...)
3 = condominium – timer
4 = condominium with immediate auto reclosing
After black-out

0 = no action
1 = closing
Soft start

0 = disabled
1 = enabled

Second wing delay
Amplitude of slowing down (0 = disabled)

P = personalized during learning
0...100% = percentage of stroke

Anti slip
Number of motors

1 = 1 motor
2 = 2 motors
6.2 Advanced menu:
MENU
..
First coupling between Bluetooth device and control unit
Electrical brake activation time
..
0 = disabled
1 - 100= enabled
Functioning of closing photocell PHOTO1 moving from closed
..
0 = Check PHOTO1
1 = The gate opens also with PHOTO1 busy
6-1622189
rev.8
12/09/2022
DESCRIPTION
DESCRIPTION
ITA
ENG
FRA
SELECTABLE
SELECTABLE
ESP
DEU
POR
Ex. Base menu
Ex. Advanced menu
VALUES
DEFAULT
min-max
0-900
0
0-30
0
0-100
0
10-100
100
0
0-1
0-4
0
0-1
0
0-1
0
0-300
2
0-100
15
0-300
0
1-2
2