6.2 Advanced menu:
MENU
Functioning of opening photocell PHOTO2
..
0 = Enabled in opening and closing OP/CL
1 = Enabled only in opening OP
Photocells test
0 = disabled
..
1 = enabled PHOTO1
2 = enabled PHOTO2
3 = enabled PHOTO1 and PHOTO2
Safety edge type
..
0 = contact (NC)
1 = resistive (8k2)
Operation mode of safety edge
0= working only in closing with inversion of movement
..
1 = stops the automation (both opening and closing) and free the obstacle (short
inversion)
Safety edge test
..
0 = disabled
1 = enabled
..
Partial opening
..
Auto reclosing time from partial opening (0 = disabled)
Blinker output mode
..
0 = Fix
1 = Blinking
..
Pre-flashing time (0 = disabled)
Courtesy ligth settings
0 = At the end of movement for a TCY time
1 = On if the gate is not closed + TCY time
..
2 = On if courtesy light timer (TCY) not expired
3 = Open gate light on/off
4 = Open gate light with proportional flashing
..
Courtesy light time
Dead-man
..
0 = disabled
1 = enabled
Setting threshold of cycles for assistance request. Once limit is reached the next
..
cycles will be done with fast blinking (only if enabled) (0 = disabled)
Continuous blinking for assistance request (done only with closed gate).
..
0 = disabled
1 = enabled
..
Water-hammer in opening phase (0 = disabled)
..
Water-hammer in closing phase (0 = disabled)
..
Time of pressure in closed for hydraulic motors (0 = disabled)
Electrical lock mode
0 = disabled
..
1 = Active Electrical lock without preventive activation
2 = Active Electrical lock with preventive activation
3 = Magnetic Electrical Lock
..
Viewing of the memory location for a single transmitter
..
Cancellation of a single transmitter
Restore default settings, enter to modify the parameter and then keep pressed the
..
MENU button, a count down appears that ends with on the display
Cancelling all transmitters, enter to modify the parameter and then keep pressed
..
the MENU button, a count down appears that ends with on the display
6-1622189
rev.8
12/09/2022
DESCRIPTION
ITA
ENG
FRA
SELECTABLE
ESP
DEU
POR
VALUES
DEFAULT
min-max
0-1
0
0-3
0
0-1
0
0-1
0
0-1
0
0-100
30
0-900
20
0-1
1
0-10
0
0-4
0
0-900
0
0-1
0
0-100
0
0-1
0
0-100
0
0-100
0
0-480
0
0-3
0
0-999
0-999
UNITS
%
s
s
s
x1000
cicli
x100
ms
x100
ms
minuti
7 / 12