6
Operation
6.1
Manual operation
(4)
Manual operation LED
(5)
Manual operation LED (only with Duo)
(9)
Pump 1 button
(10)
Pump 2 button (on Duo only)
Manual operation can be activated with button (9) / (10). The
wastewater pump is no longer switched on automatically.
If manual operation is switched on during the pumping
process, the wastewater pump switches off.
Activate manual operation
Press button (9) / (10), the manual operation LED (4) / (5)
flashes orange.
The wastewater pump can be switched on as follows when
manual operation is activated:
Switching on briefly
Press button (9) / (10) 1x.
The wastewater pump will be switched on for a short
period.
Switching on for longer
Press and keep button (9) / (10) pressed for as long as
the wastewater pump is to be switched on.
The wastewater pump is switched on.
If manual operation is not used for a certain period of time
(5 minutes), the control unit reactivates automatic opera-
tion.
6.2
Automatic operation
The system is in automatic operation, if there are no errors
detected and the operating LED (1) is illuminated in green.
The wastewater pump is switched on and off in accordance
with the wastewater level.
6.3
Overview of LED displays - Information
Flashing pattern LED 1 - 5
Flashing
Lights up / switched on
Switched off
Flashing alternately
Flashing simultaneously