PERFORMANCE DATA

Important notice: read performance data and compare the
capabilities of the system with your actual water treatment
requirements. It is recommended that the supply water be tested,
before installing a water treatment system, to determine your water
treatment needs.
Test conditions
Flow rate
F1000-DFB
= 2,83 Lpm
F1000-B1B
= 2,27 Lpm

Filter capacity

F1000-DFB
= 2'839 L
F1000-B1B
= 2'839 L
Inlet pressure
= 4,1 bar
Temperature
= 20°C+/- 2,5°C
Testing was performed under standard laboratory conditions, actual
performance may vary,
Operating requirements for F1000-DFB and F1000-B1B systems:
Pressure
= 2,75–6,89 bar
Temperature
= 4,4–37,8°C
F1000-DFB SYSTEM INSTALLED WITH
FDF1-RC FILTER CARTRIDGE
This system have been tested according to NSF/ANSI 42 for
reduction of the substances listed below. The concentration of the
indicated substances in water entering the system was reduced to
a concentration less than or equal to the permissible limit for water
exiting the system, as specified in NSF/ANSI 42.
Model F1000-DFB
Max. permissible
Influent challenge
Substance
product water
concentration
concentration
Standard 42
Chlorine
2,0 mg/L±10%
taste & odor
Flow rate = 2,8 Lpm; capacity = 2'839 L or 12 months
Testing was performed under standard laboratory conditions, actual
performance may vary.
The Model F1000-DFB is Tested and Certified by NSF International
against NSF/ANSI Standard 42 and CSA B483.1 for the reduction
of substances specified on the Performance Data Sheet.
C
US
8 • F1000-DFB, F1000-B1B Filtration systems instruction manual
Reduction
Minimum
Average
requirements
reduction
reduction
≥50%
88,8%
CARTRIDGE SEQUENCE
F1000-DFB
F1000-B1B SYSTEM INSTALLED WITH
F1B1- RC FILTER CARTRIDGE
This system has been tested according to NSF/ANSI 42 and 53 for
reduction of the substances listed below. The concentration of the
indicated substances in water entering the system was reduced to
a concentration less than or equal to the permissible limit for water
exiting the system, as specified in NSF/ANSI 42 and 53.
Model F1000-B1B
Max. permissible
Influent challenge
Substance
product water
concentration
concentration
Standard 42
Chlorine
2,0 mg/L±10%
taste & odor
Particulates
at least 10'000
(0,5-<1uM)
particulates/mL
class 1*
Standard 53
Cysts **
Minimum 50'000/L
Atrazine
0,009 mg/L ± 10%
0,003 mg/L
Lead (pH
0,15 mg/L ± 10%
0,010 mg/L
6,5)
Lead (pH
0,15 mg/L ± 10%
0,010 mg/L
8,5)
Lindane
0,002 mg/L ± 10%
0,0002 mg/L
Flow rate = 2,2 Lpm; capacity = 2'839 L or 12 months
Testing was performed under standard laboratory conditions, actual
performance may vary.
* Reduces particles as small as 0,5-1 micron in size by mechanical
means
** NSF/ANSI Standard 53 certified to reduce cysts such as
Cryptosporidium and Giardia by mechanical means.
The Model F1000-B1B is Tested and Certified by NSF International
against NSF/ANSI Standard 42, 53, and CSA B483.1 for the
reduction of substances specified on the Performance Data Sheet.
C
US
EPA Est. 082989-CHN-001
F1000-B1B
Reduction
Minimum
Average
requirements
reduction
reduction
≥50%
95,9%
>85%
97,9%
99,95%
99,97%
99,99%
90,5%
93,7%
99,3%
99,9%
99,3%
99,6%
94,8%
97,4%