Pentair F1000-B1B Manuel D'utilisation page 6

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 10
INSTALLATION IS NOW COMPLETE.
FILTER CARTRIDGES REPLACEMENT
NOTE: The life of the filter cartridges depends on water
volume used and the quality of the feed water. It is
recommended that the filter cartridges be replaced
every 6-12 months, or when there is a noticeable
change in taste, odor, or flow of filtered water.
Ensure the correct cartridge is purchased for the
system.
Model F1000-DFB uses FDF1-RC replacement cartridge
Model F1000-B1B uses F1B1-RC replacement cartridge
8. Cartridge replacement
A. Relieve pressure by turning off the water supply to the
system and opening a faucet until water flow stops. Place a
bucket or towel under the system to catch any water drips
(figure 8a).
B. Lift the locking bar upward until the filter cartridge
disengages from the filter head assembly (figure 8b).
C. Pull the cartridge away from the filter head assembly and
ensure the locking bar remains in the fully up position
(figure 8c).
D. Align the ports on the filter cartridge with the ports in the
filter head assembly. Slide the cartridge filter towards into
the filter head assembly engaging with the locking bar
causing it to drop forward and down. (figure 8d).
E. Pull down the locking bar until it snaps into place
(figure 8e).
NOTE: See placing the system into operation section for
remaining steps.
TROUBLESHOOTING
Leaks between filter head assembly and filter
cartridge
1. Relieve pressure by turning off the water supply to the
system and opening faucet until water flow stops. Place a
bucket or towel under the system to catch any water drips.
2. Remove cartridge and inspect O-rings to make sure they
are seated and clean.
3. Install filter cartridge. Place system into operation and
check for leaks. If leaks persist, turn off the water supply
and contact your distributor.
Leaks from tubing fittings
1. Relieve pressure by turning off the water supply to the
system and opening faucet until water flow stops. Place a
bucket or towel under the system to catch any water drips.
2. Depress collet on system or inlet supply adapter tubing
fittings and pull tubing from fitting. Inspect surface of
tubing for scratches or debris. Clean or cut back tubing to
access clean surface.
3. Wet the end of the inlet tubing and press into the inlet
fitting of the system. Ensure the tubing is fully pushed past
the fitting O-rings. Place system into operation and check
for leaks. If leaks persist, turn off the water supply and
contact your distributor.
6 • F1000-DFB, F1000-B1B Filtration systems instruction manual
8a
8b
8d
8c
8e

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

F1000-dfb

Table des Matières