L = Lampeggiatore
Feu clignotant
Blinker
Blinklicht
J4
J1
J2
J3
J1 => AERIAL
Radio aerial
COM
Common contact
PHOT.1 NC
Photocells contact (NC)
J2 => STOP
Contact, stop pushbutton (NC)
OPEN
Contact, open pushbutton (NA)
CLOSE
Contact, close pushbutton (NA)
K BUTT.
Contact, single pulse (NA)
PED. BUTT.
Contact, pedestrian gate pushbutton (NA)
A+A-
Accessories supply 24 Vdc
SIGNAL
Lamp, open gate 3W max
Connection warning buzzer (24 Vdc max 200 mA)
Flasher (max 20W 24 Vdc) - cod. ACG7061
SIGN
Low battery led
J3 => SEC.LOCK
Connector for safety connection of manual decoupling
J4 => EXP.24V
Connector for EXPANDER 24V card (cod. ACG5471) or
EXPANDER PLEX 24V (cod. ACG5473)
J5 => RADIO
Connector for radio receiver (model KS 24V)
J5 => RADIO
Radio receiver module (model KS 24V CRX)
ELECTRIC CONNECTIONS
+
-
L
Security Lock
LOW
J5
J6
SPEED
JP1
J7
JP2
A - CONNECTIONS
Wiring and fixing of power
supply cable
J8
J9
C.S.
J6 =>
DO NOT TOUCH THE BRIDGE!
IF REMOVED THE ACTUATOR WILL NOT OPERATE
J7 =>
DO NOT TOUCH THE BRIDGE!
IF REMOVED THE ACTUATOR WILL NOT OPERATE
J8 => BATTERY CHARGER Connector for battery charge card
J9 => ENCODER Connector for connection of the encoder
J10 => SEC.TRANSF. Connector for transformer secondary coil
J11 => Plug connector for connection of travel end switch
LSO
Travel end contact for stopping of opening motion
COM.
Common contact
LSC
Travel end contact for stopping of closure motion
J12 => MOTOR
Motor supply
LOW SPEED => Low speed adjustment trimmer
C.S. =>
Current sensor adjustment trimmer
JP1 =>
Reset
JP2 =>
DO NOT TOUCH THE BRIDGES!
IF REMOVED THE ACTUATOR WILL NOT OPERATE
Transformer
LSC
LSO
M
M = Motore DC
Moteur DC
Motor DC
Motor DC
ELECTRONIC BOARD
KS 24V
Code BC07071
J10
J11
J12