G
ELECTRIC CONNECTIONS
B
POINT A - CONTROL PANEL FEATURES
J1
N -L1
J2
A+ TEST
A +
A -
PHOT. NC
EDGE NC
K BUTT.
PED. BUTT.
COM
LOCK
J3
AERIAL
COM
BUZZER
SIGNAL
J4
U - MOTOR 2
V-W - MOTOR 2
U - MOTOR 1
V-W - MOTOR 1
SW T2
J5
SW RADIO
J6
J7
PROBE
RADIO
J8
JP17
S3
PROG
TR1
TORQUE
LOW SPEED
TR2
ON
TR2
TR1
S3
J8
J5
JP1
JP2
JP3
J6
J3
J7
J2
Main power supply 230 Vac 50/60 Hz (120V/60Hz upon request)
Safety strip self-test power supply +24Vdc
Accessories power supply +24Vdc
Accessories power supply -24Vdc
Photocells contact (NC)
Safety strip contact (NC)
Single pulse contact (NO)
Pedestrian opening contact (NO)
Common contact (common line for all the command and safety inputs)
Electric lock connection (MAX 15W 12V)
Radio Antenna
Common contact (common line for all the command and safety inputs)
Buzzer contact (24Vdc max 200 mA)
Gate open state output indicator (24Vdc 3W max)
Flashing light (max 40W )
MOTOR 2 (BLUE WIRE) COMMON CONNECTION
MOTOR 2 INVERTERS (BROWN/V and BLACK/W WIRES) AND CAPACITOR CONNECTIONS
MOTOR 1 (BLUE WIRE) COMMON CONNECTION
MOTOR 1 INVERTERS (BROWN/V and BLACK/W WIRES) AND CAPACITOR CONNECTIONS
DO NOT REMOVE ANY JUMPER!
OTHERWISE THE OPERATOR WILL NOT WORK!
(only CRX control board)
DO NOT REMOVE ANY JUMPER!
OTHERWISE THE OPERATOR WILL NOT WORK!
Not available
Built-in radio module (model CRX), or connector for radio receiver RIB, 24Vdc supply
To select 1 motor (M1) or 2 motors (M1 and M2)
Programming button
Electronic torque regulator
Electronic regulator for low speed on approach motor
34
JP17
J4
J1
electric board T2