Nut does not rest against nosepiece
Nut unscrews again
Battery switched off because it has been idle
for longer than 21 days
Battery discharged
Set blind rivet nut is loose
Cause
Setting stroke y too short
Switch K released too early
Threaded mandrel is not unscrewed
Cause
Setting stroke adjusted incorrectly
Battery discharged
Red lamp indicates fault
When pressing the trigger button
Cause
Blind rivet nut setting tool not in front end position
During pulling operation
Cause
Overload
Electronics overheated
Battery discharged
After releasing the trigger button
Cause
Front end position not reached
Caution!
If faults occur that are indicated by the red lamp and cannot be rectified as described above, have the blind
rivet nut setting tool repaired by a skilled technician or send it in to the manufacturer.
.
(see Point 2.7.1)
While it is screwed on, hold the nut until the tool stops
Keep switch K pressed until the tool stops
Place battery in the charger for 2 minutes (see 3.4)
Charge battery, replace if necessary (see Point 3.3/3.4)
Corrective measures
Increase setting stroke y (see Point 2.7.2)
Keep switch K pressed until automatic chan- geover and
unscrewing are finished (see Point 2.7)
Decrease setting stroke y (see Point 2.7.2); if necessary
use hexagon screwdriver 8 to unscrew threaded mandrel
A (see Fig. 1)
Charge battery; replace if necessary
Corrective measures
Use tool within working range as specified in table (see 2.6.)
Allow blind rivet nut setting tool to cool down in air
Charge or replace
Corrective measures
Screw together mechanical parts
www.degometal.com
Corrective measures
Corrective measures
Release trigger button