KitchenAid KDRS505SS Instructions Pour L'installation page 13

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Use this method for:
New branch-circuit installations (1996 NEC)
Mobile homes
Recreational vehicles
In an area where local codes prohibit grounding through the
neutral
1. Part of metal ground strap must be cut out and removed.
A. Metal ground strap
B. Discard
C. Ground-link screw
2. Use Phillips screwdriver to remove the ground-link screw from
the back of the range. Save the ground-link screw and the end
of the ground link under the screw.
3. Feed the power supply cord through the strain relief in the
cord/conduit plate on bottom of range. Allow enough slack to
easily attach the wiring to the terminal block.
A
C
A. Terminal block
B. Ground-link screw
C. Cord/conduit plate
D. Power supply cord wires
4-wire connection: Power Supply Cord
4. Use Phillips screwdriver to connect the green ground wire
5. Use ³⁄₈" nut driver to connect the neutral (white) wire to the
A
B
C
6. Connect line 1 (black) and line 2 (red) wires to the outer
7. Securely tighten hex nuts.
8. Replace terminal block access cover.
B
D
from the power supply cord to the range with the ground-link
screw. The ground wire must be attached first.
center terminal block post with one of the 10–32 hex nuts.
A
B
C
D
A. 10–32 hex nut
B. Ground-link screw
C. Line 1 (black)
terminal block posts with 10-32 hex nuts.
NOTE: For power supply cord replacement, use only a power
cord rated at 250 volts minimum, 40 amps or 50 amps that is
marked for use with nominal 1³⁄₈" (3.5 cm) diameter
connection opening, with ring terminals and marked for use
with ranges.
F
E
D. Green ground wire
E. Neutral (center) wire
F. Line 2 (red)
13