Cursor Buttons; Menues - DENTSPLY MULTIMAT C Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Caution !
The command "Start" is accepted in any lift position.
If the steps "Drying" and "Preheating" are selected,
the order to start is saved until the preheating temperature is
reached.
Note:
If any invalid firing data were entered, the program will not start.
An acoustic signal sounds and the display shows the invalid
value flashing. Check entered firing data.
Button "R"
Press this button and enter the program number (01– 99) to
display the desired program.
After pressing this button, the program number display flashes
for one minute. During this time, the two-digit program number
must be entered via the numeric keypad.
Caution !
Program numbers lower than 10 must be entered
with a leading zero (01– 09).
Button Lift " "
Press the button " " to move the lift upwards.
Button Lift " "
Press the button " " to move the lift downwards.
At the end of the program, press the button " " in the lower lift
position to start the individual rapid cooling.
Button "S"
Values in the display are saved to a program number.
After pressing this button, the program number display flashes
for one minute. During this time, the two-digit program number
must be entered via the numeric keypad.
Caution !
Program numbers lower than 10 must be entered
with a leading zero (01– 09).
Button "E"
Pressing this button opens the "Edit" function and the flashing
cursor is displayed. The cursor flashes for one minute, allowing
you to enter or alter data.
Use the cursor buttons to move the cursor in the display.
Button "C"
Press this button to:
• delete a wrong entry
• switch off rapid cooling
• confirm an error message
• abort the safety question when loading fixed programs
• abort a vacuum
• abort post-firing in the "View" function.
32

Cursor buttons

Press these buttons to move the cursor within the display.
Pressing and holding one of the buttons
matic movement of the cursor.

5.5 Menues

The menu provides all functions that cannot be executed directly.
It includes the screen forms shown below, containing the menu
name in the first line and a sub-menu selection or a parameter in
the second line. Since only one sub-menu can be displayed at a
time, use the buttons
display. Press the button "E" to branch off into the selected sub-
menu. Select a default setting with the buttons
change a value with the button "C". Press the button
accept the changes or press the button "M" repeatedly until the
program is displayed again. The following section describes the
function of the individual buttons for every remplate:
Settings:
Menu:
Configuration
Instrument parameters
Delete program memory
Load fixed programs
Configuration:
Contrast
YY
Print
optional
Rapid cooling
Yes/No
Signal tone
Yes/No
Language
YYYY
Fahrenheit
Yes/No
Standby
Yes/No
Instrument parameters:
Service Code
Op. hrs. muffle YYYY
Op. hrs. pump YYYY
Calibration
offset
ZZ
Frequency
50/60 Hz
Delete program memory
Delete all programs ?
Jes = E
No = C
or
causes auto-
to bring the other sub-menus to the
or
= next sub-menu
= previous sub-menu
E
= select sub-menu
M = back to main menu
= next parameter
= previous parameter
= select default or
change contrast
M = back to main menu
= next parameter
= previous parameter
0-9 and C = change values
(
C
= delete values (YYYY, ZZ)
M = back to main menu
= increasing value (ZZ)
= decreasing value (ZZ)
= next sub-menu
= previous sub-menu
E
= select sub-menu
M = back to main menu
Safety question when
deleting fixed programs.
E
= Delete and back to
main menu
C
= back to main menu
M = back to main menu
, or
or
to
)

Publicité

Table des Matières
loading