m
CHIMNEY CAPS - DISTANCES AND POSITIONING
Inclination of the roof
α α α α
15°
30°
45°
60°
6.

CONNECTION TO THE CHIMNEY

For safety reasons the door of the appliances with constructive system 1, must be opened only for the
loading of the fuel or for removing the ashes, while during the operation and the rest, the door of the hearth
must remain closed.
The appliances with constructive system 2 must be connected to their own flue. The operating with open
door is allowed under supervision.
The connection pipe to the flue must be the shortest possible, right, tight and according to the current
regulations.
1190000 – EN
10 m
(1) The chimney cap must not show hindrances within 10 m from
walls, pitches and trees. Otherwise raise it of at least 1 m over the
hindrance.
The chimney cap must exceed the ridge of the roof of at least 1 m.
>A
H min.
(1)Asse colmo
α
Distance between the roof ridge and the
stack
A (m)
< 1,85 m
> 1,85 m
< 1,50 m
> 1,50 m
< 1,30 m
> 1,30 m
< 1,20 m
> 1,20 m
> _ A
0,5 m
(2)Tetto
(1) Ridge axis
(2) Roof
UNI 10683/98
Minimum height of the stack
(measured from the outlet )
H (m)
0,50 m
above the roof ridge
1,00 m
from the roof
0,50 m
above the roof ridge
1,30 m
from the roof
0,50 m
above the roof ridge
2,00 m
from the roof
0,50 m
above the roof ridge
2,60 m
from the roof
Picture 5
Picture 6