Use
EN
Before you start
•
Switch on the appliance at the mains consumer unit. The appliance is ready for use.
WARNING: Read the instructions before using the appliance.
Function & Settings
•
Flame safety device (FSD): Stops the gas supply to the gas hob when the flame goes out.
•
Auto ignition.
Injector Table
Gas Category
GB & IE: II2H3+ (G20 20 mbar, G30 28-30 mbar, G31 37 mbar)
FR: II2E+3+ (G20 20 mbar, G25 25 mbar, G30 28-30 mbar, G31 37 mbar)
ES & PT: II2H3+ (G20 20 mbar, G30 28-30 mbar, G31 37 mbar)
RO: II2H3B/P (G20 20 mbar, G30 30 mbar, G31 30 mbar)
PL: II2ELs3B/P (G20 20 mbar, G2.350 13 mbar, G30 37 mbar, G31 37mbar)
Type of gas used
NATURAL GAS
(Methane)
G20
NATURAL GAS
(Methane/
Nitrogen)
G25
Type of
Injector
burner
marking
Auxiliary
0.78 mm
Semi-Rapid
1.00 mm
Rapid
1.28 mm
Auxiliary
0.78 mm
Semi-Rapid
1.00 mm
Rapid
1.28 mm
Rated
Rated
thermal
consumption
flow
rate kW
1
95 lt/h
1.75
167 lt/h
3.5
286 lt/h
1
111 It/h
1.75
195 It/h
3.5
333 It/h
30
Reduced
Gas
heat
pressure
capacity
rating
kW
(mbar)
0.60
0.86
20
1.84
0.56
0.82
25
1.62