EN
13
TROUBLESHOOTING
Problem
The guide bar and
the chain become
hot and release
smoke.
The motor runs
but the chain does
not rotate.
Possible cause
Solution
The chain is too
Adjust the chain
tight.
tension.
The oil tank is
Add lubricants.
empty.
Contamination
Remove the guide
causes a blockage
bar and clean the
of the discharge
discharge port.
port.
Contamination
Clean the oil tank.
causes a blockage
Add new lubri-
of the oil tank.
cant.
Contamination
Clean the guide
causes a blockage
bar and the oil
of the guide bar
tank cap.
and the oil tank
cap.
Contamination
Clean the sprocket
causes a blockage
and the guide
of the sprocket or
wheels.
guide wheels.
The chain is too
Adjust the chain
tight.
tension.
The guide bar and
Replace the guide
the chain are dam-
bar and the chain
aged.
if it is necessary.
1. Pull the mains
plug out of the
socket.
2. Remove the
guide bar cov-
er.
3. Remove the
bar and saw
chain.
The motor is dam-
4. Clean the ma-
aged.
chine.
5. Re-start the
machine.
If the sprocket ro-
tates, it means the
motor works prop-
erly. If not, call
service center.
English
Problem
The motor runs
and the chain ro-
tates, but the chain
does not cut.
The machine does
not start.
The motor runs,
but the chain does
not cut correctly,
or the motor stops
after around 3 sec-
onds.
14
TECHNICAL DATA
Motor
No load speed
Guide bar length
Chain pitch
Chain gauge
Drive links
Chain oil capacity
Weight
Chain
Guide bar
14
Possible cause
Solution
Sharpen or replace
The chain is blunt.
the saw chain.
Turn the chain
The chain is in the
loop to the other
incorrect direction.
direction.
The chain is tight
Adjust the chain
or loose.
tension.
1. Push the lock-
out button and
The lock-out but-
hold it.
ton and the trigger
are not pushed at
2. Push the trig-
the same time.
ger to start the
machine.
Release the trigger
The machine is in
and start the ma-
the protection
chine again. Do
mode to protect
not force the ma-
the PCB.
chine to cut.
Lubricate the
chain to decrease
the friction. Do
The chain is not
not let the guide
lubricated.
bar and the chain
operate without
sufficient lubri-
cant.
120 V AC, 60 Hz, 10.5
Amp
8000±10% RPM
14" (350 mm)
3/8" LP (9.5 mm)
0.05" (1.27 mm)
52
150 ml
7.9 lbs (3.6 kg)
91PJ052X/CL15052X
140SDEA041/
M1501452-1041TL(DCR14
B-050-3/8LP-52-F)