Blower connection at hood:
1. Run 2-wire plus ground power cable from
the exterior blower to the hood's wiring box
marked "motor connection".
2. Remove the cover from the wiring box and
remove one knockout.
3. Feed 6" of cable through the knockout
opening and secure the cable to the wiring
box with an appropriate connector.
4. Make electrical connections at the hood.
Connect white-to-white, red-to-black and
green-to-ground.
5. Replace the wiring box cover and screws.
make sure wires are not pinched between
the cover and box.
Exterior blower connection:
1. Make electrical connections at the exterior
blower (see instructions provided with the
exterior blower).
Power connection at hood:
1. Plug the power cord into the electrical wall
receptacle.

CONNECT DUCTWORK

1. Use mounting screws (4,8x38mm) and wall
anchors to secure flue mounting bracket
to the ceiling or wall as shown.
2. Use 8" round metal duct to connect the
discharge collar on the hood to the
ductwork above.
3. Use duct tape to make all joints secure
and air tight.
4. Connect the upper flue to the flue mounting
bracket with mounting screws (3,9x9,5mm)
provided.
5. Slide the lower flue downward, until it fits
properly around hood.
6. Secure lower flue to hood with mounting
screws (3,9x9,5mm) provided.
FASTEN FLUE TO
HOOD & FLUE
MOUNTING BRACKET
WITH MOUNTING
SCREWS
(3,9x9,5mm)
BLOWER CONNECTION AT HOOD
CONNECT:
WHITE-TO-WHITE,
RED-TO-BLACK,
GREEN-TO-GROUND.
BOX MARKED
"MOTOR
CONNECTION"
MOUNTING
SCREWS
(4,8x38mm)
- 7 -
Exterior blower
FLUE MOUNTING
BRACKET
DECORATIVE
FLUE
DUCT TAPE
8" ROUND
METAL DUCT