WIRING
Note: This range hood must be properly
grounded. The unit should be installed by a
qualified electrician in accordance with all
applicable national and local electrical
codes.
1. Remove the wiring box cover. Remove a
knockout from the wiring box.
2. Feed 6" of power cable through the knock-
out opening and secure cable to the wiring
box with an appropriate connector.
3. Make electrical connections. Connect white
to white, black to black and green to green.
4. Replace wiring box cover and screws. Make
sure that wires are not pinched between
cover and box.
CONNECT DUCTWORK
1. Use screws and wall anchors to secure flue
mounting bracket to the ceiling and wall as
shown.
2. Use 6" round steel duct to connect the duct
collar on the hood to the ductwork above.
3. Use duct tape to make all joints secure and
air tight.
Connect the upper section of decorative
4.
flue to the bracket with screws provided.
5. Slide the lower section of decorative flue
downward, until it fits properly around hood.
6. Secure decorative flue to hood with screws
provided.
FASTEN
FLUE TO
UPPER
BRACKET
WITH
SCREWS
- 5 -
WIRING BOX
COVER
DUCT COLLAR
FLUE
MOUNTING
BRACKET
DECORATIVE
FLUE
DUCT TAPE
6" ROUND
STEEL DUCT