I N S T A L L A T I O N
5.3

Mounting the heating rods

E N
NOTE:
Damage to the heating rods!
The heating rods are extremely fragile.
▷ Handle the heating rods with extreme caution!
▷ It is essential to avoid jolting, bending or turn-
ing of the heating rods!
▷ One after the other, remove one heating rod
from its packaging and insert it from above into
one of the openings in the corners of the fur-
nace ceiling.
The connection terminals must run parallel to
the front of the furnace and the heating rods
body must face against the furnace ceiling, as
shown below.
Fig. 7
Mounting a heating rod
44
▷ Screw the connection terminals of the heating
rods to the metal connection strips (tightening
torque approx. 4 Nm).
Fig. 8
Screwing the metal connection strips on