2. TECHNICAL REQUIREMENTS
EN
2.6 Installation cutout features:
Stainless exterior Pro
(European standard cutout width)
A
Minimum cutout height
2134 mm (84")
Minimum cutout width
36" model: 900 mm (35 1/2")
30" model: 750 mm (29 5/8")
24" model: 600 mm (23 3/4")
Depth with door
635 mm (25 ")
Area to be left clear for the anti-tipping brackets
127 mm (5") for both right and left sides
B
Appliance height
2120 mm (83 1/2") + 25 mm (1")
14
A
100 (4")
140 (5 ½")
140 (5 ½")
100 (4")
A
A
When installing
our top
compressor
models in a new
construction, it is
36": 900 mm (35 ½")
recommended to
use the European
30": 750 mm (29 ⅝")
min 2134
"cutout"
(84")
dimensions
100 (4")
140 (5 ½")
140 (5 ½")
100 (4")
24": 600 mm (23 ¾")
to achieve a
A
A
minimal gap on
the lateral sides
and avoid the
need to use the
J-profile trim kit.
Installing in the
36": 900 mm (35 ½")
unit in a standard
North American
30": 750 mm (29 ⅝")
min 2134
"cutout" without
635 (25")
(84")
the J-profile trim
24": 600 mm (23 ¾")
kit, will result
in a larger gap
along the cabinet
36" model: 1470 mm (57 ⅞")
opening.
30" model: 1320 mm (52")
2120 (83 ½")
24" model: 1170 mm (46")
+25 (1")
1016 (40")
635 (25")
B
613 (24 ⅛")
+25 (1")
2120 (83 ½")
560 (22")
+25 (1")
693 (27 ¼")
613 (24 ⅛")
+25 (1")
560 (22")
693 (27 ¼")
Door Swing Clearance
36" model: 1470 mm (57 ⅞")
30" model: 1320 mm (52")
24" model: 1170 mm (46")
195 (7 ⅝")
8 (⅜")
36" model: 230 mm (9")
30" model: 195 mm (7 ¾")
24" model: 160 mm (6 ¼")
1296
(50")
8 (⅜")
195 (7 ⅝")
8 (⅜")
516
(20 ⅜")
97 (3 ⅞")
+ 25 (1")
1296
(50")
8 (⅜")
516
(20 ⅜")
97 (3 ⅞")
+ 25 (1")
Minimum distance from
the wall (hinge side)
36" model: 230 mm (9")
30" model: 195 mm (7 ¾")
24" model: 160 mm (6 ¼")
1016 (40")
10 mm (⅜")
635 mm (25")
560 mm (22")
75 mm (3")
58 mm (2 ¼")
36"
model: 899 mm
(35 ⅜")
30" model: 749 mm (29 ½")
24"
model: 599 mm
(23 ⅝")
If the units are to be installed inside
a cutout or within an enclosed
structure, it is necessary to design
a ventilation shaft at the back of the
cutout to assure proper ventilation at
min 10 (⅜")
the back of the unit.
Cross-sectional chimney ventilation
area should equal 200cm² (31in²).
EN
635 mm (25")
560 mm (22")
75 mm (3")
15