Installation Cutout Features: Stainless Exterior Pro (European Standard) - Fulgor Milano F7IRC36O1 Notice D'installation

Masquer les pouces Voir aussi pour F7IRC36O1:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2. TECHNICAL REQUIREMENTS
EN
2.5 Installation cutout features:
Stainless exterior Pro
(North American standard cutout width)
A
Minimum cutout height
2134 mm (84")
Minimum cutout width
36" model: 914 mm (36")
30" model: 762 mm (30")
24" model: 610 mm (24")
Depth with door
635 mm (25 ")
Area to be left clear for the anti-tipping brackets
127 mm (5") for both right and left sides
B
Appliance height
2120 mm (83 1/2") + 25 mm (1")
12
A
When installing
100 (4")
140 (5 ½")
140 (5 ½")
100 (4")
our top
compressor
A
A
models in a
standard NA
cut out it is
recommended to
use the J-profile
trim kit to close
36": 914 mm (36")
the lateral gap
100 (4")
140 (5 ½")
30": 762 mm (30")
140 (5 ½")
100 (4")
min 2134
of the appliance,
(84")
alternatively use
A
A
24": 610 mm (24")
the standard
plastic mounting
clips when
installing unit
into Euro width
cabinet. (Shown
36": 914 mm (36")
on next page)
Installing in the
30": 762 mm (30")
min 2134
unit in a standard
(84")
North American
24": 610 mm (24")
635 (25")
"cutout" without
the J-profile trim
kit, will result
36" model: 1470 mm (57 ⅞")
in a larger gap
along the cabinet
30" model: 1320 mm (52")
opening.
24" model: 1170 mm (46")
2120 (83 ½")
B
+25 (1")
1016 mm (40")
635 (25")
613 (24 ⅛")
+25 (1")
2120 (83 ½")
+25 (1")
560 (22")
693 (27 ¼")
613 (24 ⅛")
+25 (1")
560 (22")
693 (27 ¼")
Door Swing Clearance
36" model: 1470 mm (57 ⅞")
30" model: 1320 mm (52")
24" model: 1170 mm (46")
1016 mm (40")
195 (7 ⅝")
8 (⅜")
36" model: 230 mm (9")
635 mm (25")
30" model: 195 mm (7 ¾")
24" model: 160 mm (6 ¼")
560 mm (22")
1296
(50")
195 (7 ⅝")
8 (⅜")
8 (⅜")
516
(20 ⅜")
1296
97 (3 ⅞")
(50")
+ 25 (1")
8 (⅜")
516
(20 ⅜")
97 (3 ⅞")
+ 25 (1")
Minimum distance from
the wall (hinge side)
36" model: 230 mm (9")
30" model: 195 mm (7 ¾")
24" model: 160 mm (6 ¼")
10 mm (⅜")
75 mm (3")
58 mm (2 ¼")
36" model: 914 mm (36")
30" model: 762 mm (30")
24" model: 610 mm (24")
36: 914 (36")
If the units are to be installed inside
a cutout or within an enclosed
30: 762 (30")
structure, it is necessary to design
a ventilation shaft at the back of the
24: 610 (24")
cutout to assure proper ventilation at
18: 457 (18")
min 10 (⅜")
the back of the unit.
Cross-sectional chimney ventilation
area should equal 200cm² (31in²).
EN
635 mm (25")
560 mm (22")
75 mm (3")
13

Publicité

Table des Matières
loading

Table des Matières