6. INSTALLATION: BOTTOM COMPRESSOR MODELS
EN
Distance between units (A+B)
C
18" model
18" model
7/8" (22 mm)
15/16" (23.5 mm)
24" model
15/16" (23.5 mm)
B
30" model
1" (24.5 mm)
36" model
1" (25.5 mm)
1 1/16" (27 mm)
Once the appliances have been adjusted and
properly levelled, loosen the two screws holding
the sealing plate in position.
Lower the plate until flush with the floor, and re-
tighten the screws. This will ensure optimized
airflow through the condenser necessary for proper
operation.
>
Next join them at the front attaching the plastic
connecting brackets with the supplied screws
It is suggested to use two screws for connecting
each bracket; one from each side
[ 4
].
34
A
24" model
30" model
36" model
1" (24.5 mm)
1" (25.5 mm)
1" (25 mm)
1" (26 mm)
1 1/16" (27 mm)
1" (26 mm)
1 1/16" (27 mm)
1 1/8" (28 mm)
1 1/8" (28 mm)
1 1/8" (29 mm)
[ 3
].
3
>
Finish off by mounting the central profile cover
onto the central brackets, by pushing it until a click
is heard
[ 5
].
5
>
Once completed, push the units into their final
[ 6
].
position
Always mount front panels on door before pushing
the unit into its final position inside the cutout or
structure.
>
Check the levelling of the appliance, adjusting its
feet and wheels to correct it.
>
Secure the appliance to the adjacent cabinets by
fixing with the supplied brackets on the appliance
7
]. The door must be open to access the brackets
for attachment to the cabinetry.
6
4
>
Mount the covering frames onto the brackets
used to join the units, first insert them laterally and
then push firmly until a "click" is heard
[ 8
7
8
7
8
Take care as appliances will be front-
heavy and may tip before they are secured
to the adjacent furniture.
[