Safety notes
• Installation is only possible in frost-free rooms.
• The switched-mode power supply is only suitable for indoor
use.
• In the case of damage to the external connection cable of
the switched-mode power supply, the cable must be
replaced by the manufacturer or the manufacturer's
customer service department or an equally qualified person,
in order to prevent a hazard.
• Use only genuine replacement parts and accessories. The
use of other parts will result in voiding of the warranty and
the CE identification.
• The mixer spindle is mechanical and therefore not controlled
electronically.
Technical data
• Flow rate at 0.3 MPa (3 bar) flow pressure:
• Voltage supply:
100-240 V AC 50-60 Hz/6.75 V DC
• Power consumption:
• Automatic safety shut-off:
(5 - 420 s adjustable)
• Run-on time (0 - 10 s adjustable):
• Reception range with Kodak Gray Card, grey
side, 8 x 10", landscape (factory setting):
• Type of protection:
• Water connection
Electrical test data
• Software class:
• Contamination class:
• Rated surge voltage
• Temperature of ball impact test
The test for electromagnetic compatibility (interference
emission test) was performed at the rated voltage and rated
current.
General functions
• Thermal disinfection:
• Remaining battery capacity:
Programme 1 functions (factory setting)
• Cleaning mode:
• Automatic flushing:
• Thermal disinfection time:
Further pre-set programmes can be selected via the sensor
system.
Special accessories
Further settings and special functions are available via the
infrared remote control (Prod. no. 36 206).
5
Approval and conformity
This product conforms to the requirements of the
relevant EU guidelines.
The conformity declarations can be obtained from the following
address:
GROHE Deutschland Vertriebs GmbH
Zur Porta 9
D-32457 Porta Westfalica
Installation
Plaster and tile the wall, excluding the area of the structural
shell protection.
1. Cut off inspection chamber (A) flush with tiles, see fold-out
page I, Fig. [1].
Flush pipes thoroughly before and after installation
(observe EN 806).
approx. 9 l/min
2. Attach upper part of switched-mode power supply (B) to
base (B1), see Fig. [2].
2.4 W
3. Fasten frame (C) using screws (D) and washers (D1), see
60 s
Fig. [3].
4. Fasten spout (E) to wall plate (G) using screw (F), see
1 s
Fig. [4].
Connection
approx. 13cm
1. Insert filter (H) and connect hose (I) to the cold water
IP 55
isolating valve (I1), see Fig. [5].
cold - right
2. Insert filter (H) and connect hose (J) to the hot water
hot - left
isolating valve (J1).
3. Connect plug-in connector between electronics and
solenoid valve, see fold-out page II, Fig. [6].
A
4. Connect plug-in connector between electronics and
2
switched-mode power supply.
2500 V
100 °C
Open hot and cold water supply and check that
connections are watertight.
5. Insert wall plate (G) from above in the frame (C) and fasten
using screw (G1), see Fig. [7].
Setting temperature limiter
1. Remove screw (K) and detach lever (L), see Fig. [8].
activatable
2. Remove screw (M) and remove temperature limiter (N).
readable
3. Remove feather key (O) from temperature limiter (N) and
reinsert in the desired position. The grooves in temperature
limiter (N) correspond to the temperatures that can be
activatable
selected, see Fig. [9].
deactivated
Assemble in reverse order.
3.5 min
Operation
The infrared electronics emit invisible, pulsed light.
The sensor system is adjusted so that water flow is initiated
when the hands approach the vicinity of the spout.
When the hands are withdrawn from the vicinity of the spout,
water flow is stopped after 1 s (factory setting).
The range of the sensor system is dependent upon the
reflective properties of the detected object.
Automatic safety shut-off
After 60 s of continuous detection of an object, the infrared
electronics automatically stop the water flow.