Safety notes
Prevention of frost damage
When the domestic water system is drained, the thermostats
must be drained separately since non-return valves are
installed in the hot and cold water connections. For this
purpose, the mixer must be removed from the wall.
Application
Infrared fittings with thermostat are designed for hot water
supply via pressurised storage heaters and, utilised in this
way, provide the best temperature accuracy. With sufficient
power output (from 18 kW or 250 kcal/min), electric or gas
instantaneous heaters are also suitable.
Thermostats cannot be used in connection with unpressurised
storage heaters.
All thermostats are adjusted in the factory at a flow pressure
of 0.3 MPa (3 bar) on both sides.
Should temperature deviations occur on account of special
installation conditions, the thermostat must be adapted to local
conditions (see "Adjusting").
Technical data
• Minimum flow pressure
• Operating pressure max.
• Recommended flow pressure
• Test pressure
If static pressures exceed 0.5 MPa (5 bar), a pressure-
reducing valve must be installed.
• Flow rate at 0.3 MPa (3 bar) flow pressure: Approx. 9 l/min
• Minimum flow rate
• Temperature at hot water supply:
Recommended (energy saving):
• Hot water end stop
• Hot water temperature at supply connection min. 2 °C higher
than mixed water temperature
• Voltage supply:
6 V-lithium battery (type CR-P2)
• Automatic safety shut-off:
(5 - 420 s adjustable)
• Run-on time (0 - 10 s adjustable):
• Reception range with Kodak Gray Card,
grey side, 8 x 10", landscape (factory settings):
- Start / stop water flow:
• - Automatically stop water flow:
• Water connection
General functions
• Thermal disinfection:
• Remaining battery capacity:
Programme 1 functions (factory setting)
• Cleaning mode:
• Automatic flushing:
• Thermal disinfection time:
Further pre-set programmes can be selected via the sensor
system.
5
Special accessories
Further settings and special functions are available via the
infrared remote control (prod. no. 36 206).
Approval and conformity
The conformity declarations can be obtained from the following
address:
GROHE Deutschland Vertriebs GmbH
Zur Porta 9
D-32457 Porta Westfalica
Installation
Flush piping system prior and after installation of fitting
thoroughly (Consider EN 806)!
1. Install S-unions and attach the sleeve together with the
escutcheon, see fold-out page I, Fig. [1].
2. Screw-mount the mixer and test the connections for
watertightness.
3. Push the sleeve with escutcheon onto the union nut.
4. Screw the escutcheon flush against the wall.
Refer to the dimensional drawings on fold-out page I.
0.1 MPa (1 bar)
1 MPa (10 bar)
Install the spout, see Fig. [2].
0.1 – 0.5 MPa (1 - 5 bar)
Swivel range can be adjusted by means of screw (A).
1.6 MPa (16 bar)
Open hot and cold water supply and check that
connections are watertight.
Reversed connection (hot on right - cold on left). Replace
5 l/min
thermostatic compact cartridge, see Replacement Parts, fold-
max. 70 °C
out page II,Prod. no. 47 175 (1/2").
60 °C
When using this thermostatic compact cartridge,
35 °C - 45 °C
the Cool Touch function is no longer available.
Operation
60 s
The infrared electronics are set as follows at the factory:
1 s
Start water flow
Hold the hand at a distance of 3 - 7cm in front of the sensor
system.
3 - 7cm
Stop water flow
> 35cm
• 1 s after leaving the detection zone.
cold - right
• On approaching with the hand again.
hot - left
The range of the sensor system is dependent upon the
reflective properties of the detected object.
Automatic safety shut-off
activatable
readable
After 60 s of continuous detection of an object, the infrared
electronics automatically stop the water flow.
Temperature limitation
activatable
The safety stop limits the temperature range to 38 °C.
deactivated
The 38 °C limit can be overridden by pressing the button (E),
3.5 min
see fold-out page I, Fig. [3].
This product conforms to the requirements of the
relevant EU directives.