Miscellaneous: Siren
Quick Keys
Parameter
[8][2][2]
Strobe Blink
Defines the number of times that the strobe will blink in a minute .
[8][2][2][1]..[5]
Strobe Blink options
[1]: 20 times per minute.
[2]: 30 times per minute.
[3]: 40 times per minute (Default)
[8][2][3]
Strobe Arm Squawk
The time that the strobe will blink when the system is armed.
Note: If the sounder's squawk strobe is defined as NO (Refer to Adding / Deleting the
Outdoor Sounder section) this parameter will be ignored.
[8][2][4]
Siren LED
Defines the operation mode of the Status LED2.
[8][2][4][1]
Always On
The status LED2 is always on
[8][2][4][2]
Always Off
The status LED2 is deactivated
[8][2][4][3]
Follow Arm (Default)
The status LED2 is activated when any of the sounder selected partition is armed (Away
or Stay mode)
[8][2][4][4]
Follow Alarm
The status LED 2 is activated after any alarm condition
[8][2][5]
Proximity Level Response
Defines the time (seconds) for which a proximity violation must exist before the sounder
will trigger an anti approach alarm. The option 0 indicates that the proximity is deactivated.
[8][2][6]
Battery Load Test
Enables to set the time period that the ProSYS will automatically generate a Load test on
the battery.
[8][2][6][1]
Never
The system will not set a battery load test
[8][2][6][2]
Every 24 Hours (Default)
The system will set a battery load test every 24 hours.

Installer Menu: System

New System Parameters
[1][2][35]
Audible Proximity Tamper
Yes: A proximity anti approach violation will activate the sounder.
No: A proximity anti approach violation will not activate the sounder and will be regarded
as trouble by the system.
[1][2][38]
Siren Auxiliary=Tamper
Yes: A sounder auxiliary trouble will be regarded as tamper alarm by the system.
No: A sounder auxiliary trouble will be regarded as trouble by the system.
10
[4]: 50 times per minute
[5]: 60 times per minute.
Default: 01
Default: 3
Default: No
Default: No
Range: 01-20 (seconds)
Range: 0-9 seconds