Prosound - Installation Instructions; Introduction; Main Features; Installation - RISCO Group ProSound Guide D'installation Et De Programmation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

ProSound – Installation Instructions

Introduction

RISCO Group's External Sounder combines high performance and reliability with an exclusive design, making it the
perfect finishing touch for your burglary and fire alarm installations.
ProSound can be connected to any alarm system, or or it can be installed on the BUS of RISCO Group's
ProSYS/LightSYS integrated security system. When installed in conjunction with the ProSYS/LightSYS a whole
new level of remote diagnostics and control becomes available, saving you time and reducing repeat site visits.

Main Features

Long life SLT strobe (patent pending)
UV-treated vandal proof polycarbonate housing
Double skin with internal metal cover
Auto recharging battery circuit
Automatic low battery disconnection (below 10.5V)
for protection against battery deep discharge
Reverse Battery Connection Protection
Positive or negative triggering signal

Installation

The sounder should be mounted in a difficult to access location to minimize tampering risk, on a flat mounting
surface.
To mount the sounder:
IMPORTANT:
!
The sounder is designed to operate under harsh environmental conditions. However, stormy weather (e.g. heavy
rain, snow, or hail) may cause activation of the anti approach relay (RS200WAP000A). Therefore, it is
recommended to mount the sounder with anti approach protection in an area protected from rain (e.g. under the
eaves).
NOTE:
Before wiring the sounder, ensure that the connection to a power source is switched OFF.
1.
Open the front cover by removing the case locking screw located at the bottom of the unit.
2.
Hold the mounting pattern template (supplied) against the wall and mark the locations for the
mounting holes (4 mounting holes are available). Drill the desired mounting holes and place
the screw anchors.
3.
Insert the wires through the hole at the back cover.
4.
Mount the back unit to the wall using the supplied screws, 3.93.9mm, 32mm length screws
(DIN 7981 3.9X32 ZP).
5.
Remove the internal metal cover by removing the locking screw located at the bottom of the
cover.
6.
Complete all wiring and set the jumpers and DIP-switches as required.
7.
For Wall tamper insert a tamper screw into a tamper hole (Below the tamper switch)
8.
If required, connect the sounder Lamp.
9.
Insert and connect the back-up battery (SLA rechargeable 12V, 2.2 A/H, UL approved).
NOTE:
Set as default and controlled by DIP2 SW3, the back-up battery will only be activated (if needed) after first time
mains power connection.
10. Reattach the metal cover and then close the front plastic cover by reattaching the screw
located at the bottom
4
Double tamper protection (Wall & Cover)
Anti-Approach, anti foam proximity protection
(3cm) (optional)
Flexible strobe activation when connected to
RISCO Group's ProSYS / LightSYS
Remote Diagnostics and Control when connected
to RISCO Group's ProSYS / LightSYS
Dedicated trouble and anti approach outputs
Protection from power supply inverted connection

Publicité

Table des Matières
loading

Table des Matières