Installer Menu: System

New System Parameters
[1][2][35]
Audible Proximity Tamper
Yes: A proximity anti approach violation will activate the sounder.
No: A proximity anti approach violation will not activate the sounder and will be
regarded as trouble by the system.
[1][2][38]
Siren Auxiliary=Tamper
Yes: A sounder auxiliary trouble will be regarded as tamper alarm by the system.
No: A sounder auxiliary trouble will be regarded as trouble by the system.
Updated System Parameter
[1][2][13]
Alarm ZE Cut
Yes: Produces an alarm if the communication between the main panel and any
zone expander or sounder is lost. A report is transmitted to the central station.
No: No alarm occurs. The system, however, produces a local trouble indication.

User Menu: Diagnostics

The diagnostics menu enables to test parameters that reflect the operation of the sounder.
1. From the user menu press
2. Enter the Installer code (or sub-installer) and press
3. Press [9][3] to for the Siren diagnostic menu.
4. Enter the digit of the sounder that you want to test and then press
will perform the diagnostics test and a list of test parameters will appear, as indicated in
the table below.
5. Use the keys
to view the diagnostics test results.
NOTE:
The diagnostic features can be also performed from Upload/Download software, locally or remotely.
Maintenance: Siren Diagnostics
Quick Keys
Parameter
[4][9][3]
Siren Diagnostics
Battery Voltage: Display battery voltage of the selected sounder.
Battery Load: Display battery voltage under load.
Auxiliary voltage: Display input voltage of the sounder from the AUX and COM
terminals.
Bell current: Displays the bell current consumption of the selected sounder.
Charge current: Displaying the current charging from the AUX and COM
terminals. The maximum current is 200mA.