Updated System Parameter
[1][2][13]
Alarm ZE Cut
Yes: Produces an alarm if the communication between the main panel and any zone
expander or sounder is lost. A report is transmitted to the central station.
No: No alarm occurs. The system, however, produces a local trouble indication.
User Menu: Diagnostics
The diagnostics menu enables to test parameters that reflect the operation of the sounder.
1. From the user menu press
2. Enter the Installer code (or sub-installer) and press
3. Press [9][3] to for the Siren diagnostic menu.
4. Enter the digit of the sounder that you want to test and then press
perform the diagnostics test and a list of test parameters will appear, as indicated in the table
below.
5. Use the keys
NOTE:
The diagnostic features can be also performed from Upload/Download software, locally or remotely.
Maintenance: Siren Diagnostics
Quick Keys
Parameter
[4][9][3]
Siren Diagnostics
Battery Voltage: Display battery voltage of the selected sounder.
Battery Load: Display battery voltage under load.
Auxiliary voltage: Display input voltage of the sounder from the AUX and COM terminals.
Bell current: Displays the bell current consumption of the selected sounder.
Charge current: Displaying the current charging from the AUX and COM terminals. The
maximum current is 200mA.
User Menu: Sounder Version
1. From the user menu press
2. Enter the Installer code (or sub-installer) and press
3. Press [0][4] to enter the Siren version menu:
Maintenance: Siren Diagnostics
Quick Keys
Parameter
[4][0][4]
Siren Version
The siren version supplies the following information for each of the sounders in the
system:
NOTE:
If a communication trouble with the sounder occurs, the "COMMUNICATION TROUBLE"
message appears.
[4] to access the Maintenance menu.
/
/
to view the diagnostics test results.
[4] to access the Maintenance menu.
Sounder part number
Sounder Software Version
Sounder software date
Sounder software checksum
Default: Yes
/
.
/
/
.
. The system will
11