Télécharger Imprimer la page

New System Parameters - RISCO Group Watch OUT Guide D'installation

Détecteur extérieur à double technologie

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 51
Quick Keys
Parameter
[2][0][3][zzz]
MW Range options
[3][1]..[7]
1) Minimum
2) 20%
Alarm Logic
[2][0][3][zzz]
Determine the detector's logic of defining an alarm.
[4]
PIR and Microwave
[2][0][3][zzz]
Alarm is activated when both PIR and MW channels detect an alarm
[4][1]
(AND Logic)
PIR or Microwave
[2][0][3][zzz]
An alarm is activated when either PIR or MW channels detect an alarm (OR
[4][2]
Logic)
Lens Type
[2][0][3][zzz]
Defines the actual Lens of the detector
[5]
Lens Type Options
[2][0][3][zzz]
1) Wide Angle 2) Barrier / Long Range
[5][1]..[2]
Anti-Mask
[2][0][3][zzz]
Defines the operation of Anti Masking detection
[6]
Anti-Mask Options
[2][0][3][zzz]
1) Disable 2) Enable (Default)
[6][1]..[2]
Arm/Disarm
[2][0][3][zzz]
Defines the operation of the LEDs anti masking detections while the detector
[7]
is armed
No
[2][0][3][zzz]
AM (Anti masking) is enabled
[7][1]
LEDs behave according to the LEDs parameter definition
Yes
[2][0][3][zzz]
AM (anti masking) is disabled
[7][2]
LEDs are disabled
System Parameters
System: System Control
Quick Keys
Parameter
[1][2][36]
AM=Tamper
Used to determine the operation of Anti Masking detection
Yes: Anti mask violation will activate tamper alarm.
No: Anti mask violation will be regarded as trouble event.
[1][2][37]
VBR=Tamper
Used to determine the operation of the vibration detection (applicable to
versions with Vibration sensor installed)
Yes: Vibration detection will activate tamper alarm.
No: Vibration detection will be regarded as trouble event.
16
3) 40%
5) 80%
4) 60%
6) Maximum
WatchOUT DT Installation Manual
Default
7) Trimmer (MW is defined
by the trimmer setting on
the PCB)
PIR and Microwave
Wide Angle
Enable
No
Default:
No
No

Publicité