INSTALLATION

Installing/Replacing the lamp

For the installation, you need one HMI 1200/S lamp.
The lamp must only be changed when wearing appropriate protective clothing (protection glasses, protection
gloves, helmet with sight, leather apron).
The lamp life given by the manufacturer must never be exceeded. This is why you need to take notes on the
operational time of the lamp and replace the lamp in time.
Keep exchanged lamp in a protective container and remove accordingly.
During the operation, the lamp reaches temperatures of up to 600° C.
Before replacing the lamp, unplug mains lead and let the lamp cool down (approx. 10 minutes).
During the installation do not touch the glass-bulbs bare-handed! Please follow the lamp manufacturer's
notes!
Do not install lamps with a higher wattage! Lamps with a higher wattage generate temperatures the device
was not designed for. Damages caused by non-observance are not subject to warranty.
Procedure:
Step 1: Unscrew the fixation screws of the lamp cover and remove it.
Step 2: Loosen both knurled-head screws and slide the retaining tag to one side.
Step 3: Loosen the knurled-head screw on both ends of the lamp.
Step 4: If replacing the lamp, remove the old lamp from the lamp holder.
Step 5: Rotate the lamp into the lamp holder.
Step 6: Slide the retaining tag back again and tighten both knurled-head screws.
Step 7: Replace the lamp cover and tighten the fixation screws.
DANGER TO LIFE!
Only install the lamp with the device switched off!
Unplug from mains before!
CAUTION!
The lamp has to be replaced when it is damaged
or deformed due to the heat!
Do not operate this device with opened cover!