Fields Of Use; Type Of Ducting - GRUPPO PIAZZETTA 80 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

FIELDS OF USE

The ducting kit for the Gruppo Piazzetta S.p.A. connecting flue pipe, in conformity with current
standards, is suitable for connecting to any other pellet stove after adaptation of the appliance
smoke outlet connector.
The connecting flue pipe must operate in conditions of vacuum.
If there are bends or offsets appropriate inspection apertures must be installed for maintenance.
For information regarding the length of the connecting flue pipe, see the appliance instruction
booklet containing information given by the manufacturer. Do not use elements with reverse slope.
The connecting flue pipe must not cross rooms where it is prohibited to install combustion appliances,
nor in other rooms divided into compartments for fire or with the hazard of fire, or in rooms and/
or spaces that cannot be inspected. Ensure that the installed flue pipe is self-supporting, otherwise
anchor it with suitable pipe clips.
It is necessary to install the "T" connector with an inspection opening as the first element at the
pellet appliance outlet, with the exclusion of a direct connection to the chimney.
"T" connector
Using a "T" connector as the first coupling at the appliance flue outlet makes it possible to collect
condensation mixed with the sooth that deposits inside the pipe, and makes it possible to periodically
clean the ducting without disassembling the pipes. The "T" connector must be installed for proper
operation.
This connector can be purchased from Piazzetta Group dealers together with the pipes for the flue
pipe.
The flue pipe must only be used for the purpose for which it was designed.

TYPE OF DUCTING

Typical illustration
The measurements are given in mm.
For reasons of manufacture there could be slight differences from the given measurements,
a
which are therefore to be taken solely for theoretical calculation.
STANDARD
PIPE
X
Nominal size
250
Ø80
500
Ø100
1000
18
INSPECTION
PIPE
B
X
B
200
250
200
450
-
-
950
-
-
H07025750 / DT2000730 – 11
DT2010659-01
DT2010660-00
B
X
DT2030999-00