The refrigerant loop is sealed. Only a qualified technician
should attempt to service!
Do not discharge the refrigerant into the atmosphere.
⚫
⚫ R-290 (propane) is flammable and heavier than air.
The maximum refrigerant charge amount: 120g
⚫
⚫ It collects first in low areas but can be circulated by the fans.
⚫ If propane gas is present or even suspected, do not allow
untrained personnel to attempt to find the cause.
⚫ The propane gas used in the unit has no odor.
⚫ The lack of smell does not indicate a lack of escaped gas.
⚫ If a leak is detected, immediately evacuate all persons from
the store, ventilate the room and contact the local fire
department to advise them that a propane leak has occurred.
⚫ Do not let any persons back into the room until the qualified
service technician has arrived and that technician advises that
it is safe to return to the room.
⚫ No open flames, cigarettes or other possible sources of
ignition should be used inside or in the vicinity of the units.
⚫ Component parts are designed for propane and non-incentive
and non-sparking. Component parts shall only be replaced
with identical repair parts.
FAILURE TO ABIDE BY THIS WARNING COULD RESULT IN AN
EXPLOSION, DEATH, INJURY AND PROPERTY DAMAGE.