Introduction; Important; Specifications - Empire Heating Systems DV-20E-5 Instructions Pour L'installation Et Manuel Du Propriétaire

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Introduction

Always consult your local Building Department regarding
regulations, codes or ordinances which apply to the installation of
a direct vent wall furnace.
Instructions to Installer
1. Installer must leave instruction manual with owner after
installation.
2. Installer must have owner fill out and mail warranty card supplied
with furnace.
3. Installer should show owner how to start and operate furnace
and thermostat.
4. Installer must locate unit near a grounded wall receptacle for
115VAC power and must provide gas supply and vent the unit
properly for safe operation.
Warning:
Any change to this furnace or its control can be dangerous.
This is a heating appliance and any panel, door or guard
removed for servicing an appliance must be replaced prior
to operating the appliance.
General Information
This series is design certified in accordance with American National
Standard/CSA Standard Z21.86 and CSA 2.32 by the Canadian
Standards Association as a Fan Type Direct Vent Wall Furnace to
be installed according to these instructions.
Any alteration of the original design, installed other than as
shown in these instructions or use with a type of gas not shown on
the rating plate is the responsibility of the person and company
making the change.

Important

All correspondence should refer to complete Model Number, Serial
Number and type of gas.
Notice: During initial firing of this unit, oil from the heat exchanger
may bake out and smoke may occur. To prevent triggering of smoke
alarms, ventilate the room in which the unit is installed.
Installation in Residential Garages
Gas utilization equipment in residential garages shall be installed
so that all burners and burner ignition devices are located not less
than 18" (457mm) above the floor.
Such equipment shall be located, or protected, so it is not subject
Model
Input BTU/HR (KW/H) 20,000 (5.9)
Height
Width
Depth with Shroud
Gas Inlet (Pipe)
Electrical - Unit as a 5' (1.5m) 3 pronged cordset for connec-
tion to an approved 115 VAC 60HZ maximum
AMPs - 5A wall receptacle.
Page 6
INTRODUCTION

SPECIFICATIONS

DV-20E
DV-40E
40,000 (11.7)
26" (660mm)
26" (660mm)
37" (940mm)
37" (940mm)
15 3/4" (400mm) 15 3/4" (400mm)
1/2" (13mm)
1/2" (13mm)
to physical damage by a moving vehicle.
Qualified Installing Agency
Installation and replacement of gas piping, gas utilization equipment
or accessories and repair and servicing of equipment shall be
performed only by a qualified agency. The term "qualified agency"
means any individual, firm, corporation or company which either in
person or through a representative is engaged in and is responsible
for (a) the installation or replacement of gas piping or (b) the
connection, installation, repair or servicing of equipment, who is
experienced in such work, familiar with all precautions required
and has complied with all the requirements of the authority having
jurisdiction.
State of Massachusetts: The installation must be made by
a licensed plumber or gas fitter in the Commonwealth of
Massachusetts.
The installation must conform with local codes, or in the absence
of local codes, the National Fuel Gas Code, ANSI Z223.1/NFPA 54
or Natural Gas and Propane Installation Code, CSA B149.1.
*Available from the American National Standards Institute, Inc.,
11 West 42nd St., New York, NY 10036.
A manufactured home (USA only) or mobile home OEM installation
must conform with the Manufactured Home Construction and Safety
Standard, Title 24 CFR, Part 3280, or, when such a standard is not
applicable, the Standard for Manufactured Home Installations, ANSI
Z225.1, or Standard for Gas Equipped Recreational Vehicles and
Mobile Housing, CSA Z240.4.
High Altitudes
For altitudes/elevations above 2,000 feet (610m), input ratings should
be reduced at the rate of 4 percent for each 1,000 feet (305m) above
sea level, this may be accomplished by reducing manifold pressure.
The maximum allowable reduction in manifold pressure for Natural
gas shall be from 3.5" w.c. (.872kPa) to 2.8" w.c. (.697kPa). The
maximum allowable reduction in manifold pressure for Propane
(LP) gas shall be from 10.0" w.c. (2.49kPa) to 8.0" w.c. (1.99kPa).
For Canadian high altitude applications, this appliance is suitable
for installation at elevations between 0 feet (0m) and 4,500 feet
(1,372m) without change.
Accessories
Extended Vent Terminal
For walls up to 32" (813mm)
Intake/Exhaust Extension Kit
54" (1371mm) Vent Kit with 2 Elbows
54" (1371mm) Vent Kit (straight)
for Extended Vent Runs
Floor Pad
DVT-2
DVE-1
DVE-2
(use with DVE-1)
DVP-1
19562-4-0610

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Dv-40e-5

Table des Matières