WARNING
FIRE OR EXPLOSION HAZARD
If the information in these instructions is
not followed exactly, a fire or explosion
may result causing property damage,
personal injury or loss of life.
— Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch;
do not use any phone in your building.
Leave the building immediately.
Immediately call your gas supplier
from a neighbor's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the fire department.
— Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
INSTALLATION INSTRUCTIONS
AND OWNER'S MANUAL
FAN TYPE
DIRECT - VENT WALL
FURNACE MODEL:
DVC55IPXLP-1
DVC55IPXNAT-1
INSTALLER:
Leave this manual with the appliance.
CONSUMER:
Retain this manual for future reference.
WARNING
If not installed, operated and maintained
in accordance with the manufacturer's
instructions, this product could expose you
to substances in fuel or from fuel combustion
which can cause death or serious illness.
This appliance may be installed in an
aftermarket, permanently located, manufactured
home (USA only) or mobile home, where not
prohibited by state or local codes.
This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases, unless a certified kit is used.
Page 1

Publicité

Table des Matières
loading

Sommaire des Matières pour Empire Heating Systems DVC55IPXLP-1

  • Page 1 INSTALLATION INSTRUCTIONS AND OWNER’S MANUAL FAN TYPE DIRECT - VENT WALL FURNACE MODEL: DVC55IPXLP-1 DVC55IPXNAT-1 INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. WARNING If not installed, operated and maintained WARNING in accordance with the manufacturer's...
  • Page 2: Table Des Matières

    TABLE OF CONTENTS SECTION PAGE Important Safety Information .......................3 Safety Information for Users of Propane Gas ................4 Requirements for Massachusetts ....................5 Introduction ..........................6-7 Specifications ..........................7 Gas Supply ..........................8-9 Clearances ..........................9 Installation Instructions ......................10-12 Lighting Instructions ........................13 Pilot Flame Characteristics .......................14 Main Burner Flame Characteristics ..................14 Wiring ............................15 Service and Maintenance Suggestions ................
  • Page 3: Important Safety Information

    IMPORTANT SAFETY INFORMATION THIS IS A HEATING APPLIANCE DO NOT OPERATE THIS APPLIANCE WITHOUT FRONT PANEL INSTALLED. • Due to high temperatures the appliance should be • DO NOT put anything around the furnace that will located out of traffic and away from furniture and obstruct the flow of combustion and ventilation air.
  • Page 4: Safety Information For Users Of Propane Gas

    SAFETY INFORMATION FOR USERS OF PROPANE GAS Propane is a flammable gas which can cause fires and explo- SOME POINTS TO REMEMBER sions. In its natural state, propane is odorless and colorless. • Learn to recognize the odor of Propane Gas. Your local Propane You may not know all the following safety precautions which Gas Dealer can give you a "Scratch and Sniff"...
  • Page 5: Requirements For Massachusetts

    REQUIREMENTS FOR MASSACHUSETTS For all side wall horizontally vented gas fueled equipment installed SIGNAGE. A metal or plastic identification plate shall be per- in every dwelling, building or structure used in whole or in part for manently mounted to the exterior of the building at a minimum residential purposes, including those owned or operated by the height of eight (8) feet above grade directly in line with the Commonwealth and where the side wall exhaust vent termination...
  • Page 6: Introduction

    INTRODUCTION Always consult your local Building Department regarding regulations, The base referred to above does not mean the fire-proof base as codes or ordinances which apply to the installation of a direct vent used on wood stoves. The protection is for rugs that are extremely wall furnace.
  • Page 7: Specifications

    Side Outlet Kit, 10" Boot Assembly w/Register VINYL SIDING VENT KITS Part Numbers Description DV-822 Vinyl Siding Vent Kit VSK2 Vinyl Siding Vent Kit CONVERSION KITS Part Numbers Description Used On 682160 Propane to Natural DVC55IPXLP-1 682269 Natural to Propane DVC55IPXNAT-1 37403-5-0620 Page 7...
  • Page 8: Gas Supply

    GAS SUPPLY Locating Gas Supply Installing a New Main Gas Shut-Off The gas line can enter the unit either through the floor or outside Each appliance should have its own manual gas shut-off. wall. The gas line opening should be made at this time. Location A manual main gas shut-off should be located in the vicinity of the of the opening will be determined by the position of floor joists and unit.
  • Page 9: Clearances

    GAS SUPPLY (CONT'D) Attention! If one of the above procedures results in pressures in Checking Manifold Pressure excess of 1/2 psig (14" w.c.) (3.5 kPa) on the appliance gas valve, Both Propane and Natural Gas valves have a built-in pressure it will result in a hazardous condition.
  • Page 10: Installation Instructions

    INSTALLATION INSTRUCTIONS Locating Wall Opening The furnace is to be located on an outside wall. Locate wall studs so that wall opening will be located between wall studs. The furnace is 16 inches in width and normal 16 inches on center studs will not allow the furnace to be recessed into the wall unless a stud is repositioned.
  • Page 11 INSTALLATION INSTRUCTIONS (CONT'D) Cutting Vent Tubes This is the most important part of the installation. With the furnace installed on wall the 6" diameter air inlet tube and the 4" diameter flue outlet tube are to be marked and cut using the fol- lowing procedure.
  • Page 12 INSTALLATION INSTRUCTIONS (CONT'D) Reassembly And Resealing Vent-Air Intake System Installing a Vent Near a Window Ledge, When vent-air intake system is removed for servicing the furnace, Other Type of Projection or on Siding (vinyl, aluminum, etc.) the following steps will assure proper reassembly and resealing Direct vent furnaces are designed to be installed on a uniform of the vent-air intake assembly.
  • Page 13: Lighting Instructions

    LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE OPERATING WARNING If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance is equipped with an ignition device which C.
  • Page 14: Pilot Flame Characteristics

    PILOT FLAME CHARACTERISTICS The pilot flame (Figure 11) going to the spark must be large enough to completely cover the sparking area. With the proper flame, only 2 or 3 sparks will occur. More sparks indicate a small pilot flame and no ignition with spark stopping after approximately 90 seconds generally means not enough flame.
  • Page 15: Wiring

    WIRING Wiring The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1, if an external electrical source is utilized. This appliance is equipped with a three-prong [grounding] plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle.
  • Page 16: Service And Maintenance Suggestions

    SERVICE & MAINTENANCE SUGGESTIONS GENERAL: All furnaces have been fire-tested to check for proper CHECKOUT operation. This includes, main burner flame, pilot flame, fan Check out the gas control system: operation, fan control, limit control and automatic valve operation. 1. At initial installation of the appliance. If the furnace fails to function on initial installation, it is advisable to 2.
  • Page 17 SERVICE & MAINTENANCE SUGGESTIONS (CONT'D) TRIAL FOR IGNITION first main valve operator and closes the first main valve in the gas Pilot Ignition control, stopping pilot gas flow. The control system must be reset Following call for heat (system start on S8600H), the module by turning the valve off for one minute or by turning off power to the energizes the first main valve operator.
  • Page 18: Troubleshooting

    TROUBLESHOOTING Important WARNING 1. The following service procedures are provided as a general When performing the following steps, do not touch stripped end of guide. jumper or SPARK terminal. The ignition circuit generates 13,000 2. Meter readings between gas control and ignition module must volts at 25 pf load and electrical shock can result.
  • Page 19 TROUBLESHOOTING (CONT'D) 37403-5-0620 Page 19...
  • Page 20 TROUBLESHOOTING (CONT'D) Green LED Status Codes Green LED Flash Code Indicates Next System Action Recommended Service Action (X + Y) No “Call for Heat” Not applicable None Flash Fast Startup-Flame sense calibration Not applicable None Heart Beat Normal operation Not applicable None Recycle Initiate new trial for ignition.
  • Page 21: Master Parts Distributor List

    MASTER PARTS DISTRIBUTOR LIST To Order Parts Under Warranty, please contact your local Empire dealer. See the dealer locator at www.empirecomfort. com. To provide warranty service, your dealer will need your name and address, purchase date and serial number, and the nature of the problem with the unit.
  • Page 22: Parts List

    PARTS LIST PLEASE NOTE: When ordering parts, it is very important that part number and description of part coincide. Index No. Part No. Description Index No. Part No. Description 11762 Outer Casing Top M151 Gasket for Observation Hole Cover R618 Motor Mount (Four Required) DV781 Lighting Hole Cover w/Mica...
  • Page 23: Parts View

    PARTS VIEW 37403-5-0620 Page 23...
  • Page 24: Warranty

    WARRANTY Empire Comfort Systems Inc. warranties this space heating product to be free from defects at the time of purchase and for the periods specified below. Space heating products must be installed by a qualified technician and must be maintained and operated safely, in accordance with the instructions in the owner’s manual.
  • Page 25: Installateur

    INSTRUCTIONS POUR L’INSTALLATION ET MANUEL DU PROPRIÉTAIRE RADIATEUR MURAL À CIRCULATION FORCÉE AVEC UN ÉVENT DIRECT MODÈLES : DVC55IPXLP-1 DVC55IPXNAT-1 INSTALLATEUR : Laissez cette notice avec l’appareil. CONSOMMATEUR : Conservez cette notice pour consultation ultériure. AVERTISSEMENT AVERTISSEMENT Si l’installation, l’usage et l’entretien de ce produit RISQUE D’INCENDIE OU D’EXPLOSION...
  • Page 26: Kits De Ventilation De Vinyle

    KITS DE CONVERSION Numéro de parte La description Utilisé sur 682160 Propane to Naturel DVC55IPXLP-1 682269 Naturel to Propane DVC55IPXNAT-1 Installations de Gaz de Tête De Puits Certains services publics de Gaz Naturel utilisent du gaz «tête de puits». Cela peut affecter la sortie Btu de l'unité et favoriser la formation de suie.
  • Page 27: Danger D'empoisonnement Au Monoxyde De Car- Bone

    Lorsqu’un radiateur de catégorie 1 existant est retiré ou remplacé, le sys- ment indiquer les effets d’un système de ventilation de taille inadéquate tème de ventilation d’origine peut ne plus être dimensionné pour ventiler (formation de condensat, fuite, déversement, etc.) et doivent spécifier la correctement les appareils raccordés.
  • Page 28: Information De Sécurité Pour Les Utilisateurs De Propane

    INFORMATION DE SÉCURITÉ POUR LES UTILISATEURS DE PROPANE Le Propane est un gaz inflammable qui peut causer des feux et des n’y aura pas une minute à perdre, la sécurité de chacun dépendra de explosions. Dans son état naturel, le propane est inodore et sans couleur. votre savoir-faire.
  • Page 29 Agence d’Installation Qualifiée étant donné que la distance normale entre les montants du mur L’installation et le remplacement des tuyaux à gaz, des est de 16" (40.64cm) le radiateur pourra être encastré seulement équipements ou accessoires, la réparation et l'entretien de si un montant est changé...
  • Page 30 MINIMUM 4” (10.16CM) MINIMUM 4” (10.16CM) AUX MATÉRIAUX AUX MATÉRIAUX COMBUSTIBLES COMBUSTIBLES GUIDE VUE GUIDE VUE DE DESSUS DE DESSUS CAPUCHON D’ÉVENT PAS SI REGISTRES GUIDE REPRESENTÉ DE CÔTÉ NE (IDENTIQUE Á SONT PAS L’AUTRE CÔTÉ) UTILISÉS MINIMUM DE 18” (45.7CM) AUX APPAREIL PEUT APPAREIL NE PEUT PAS ÉTRE ENCASTRÉ...
  • Page 31 2. Attacher le tuyau d’échappement de 4" (10.16cm) de diamètre Emplacement de l'Alimentation Électrique sur le collet de la sortie d’échappement qui est sur la chambre Sur le bas des panneaux des côtés gauche et droit, il y a une entrée de combustion.
  • Page 32: Alimentation En Gaz

    4. Appliquer du ciment pour radiateur au collet de la sortie TUYAU D’AIR 6” ½”(13mm) (15.24CM) d’échappement de 4" (10.16cm) de diamètre et sur le collet de 4" 2 1/4” (57mm) TUYAU D’ÉCHAPPEMENT (10.16cm) de diamètre du capuchon d’évent. Attacher le tuyau de 4”...
  • Page 33 Aspect Convenable de la Flamme de la Veilleuse Méthode pour installer un collecteur de sédiment avec un adapteur en T La flamme de la veilleuse (Figure 8) allant à l'étincelle doit être assez L’emploi des connexions de gaz suivantes est recommandé: grande pour couvrir complètement la zone d'étincelle.
  • Page 34: Pose Des Fils Électriques

    Pose des Fils Électriques Si vous utilisez une source électrique extérieure, l’appareil, lorsqu’il est installé, doit avoir une prise de terre conforme avec les codes locaux ou dans l’absence de codes locaux, avec le National Electrical Code, ANSI/NFPA70 ou Canadian Electrical Code, CSA C22.1. Pour votre protection contre les dangers de chocs, cet appareil est muni d’une fiche à...
  • Page 35: Pour Votre Sécurité Lire Avant D'allumer

    POUR VOTRE SÉCURITÉ LIRE AVANT D’ALLUMER AVERTISSEMENT Si vous ne suivez pas exactement ces instructions, un feu ou une explosion peut se produire causant des dommages à la propriété, des blessures corporelles ou la mort. A. Cet appareil est muni d'un dispositif d'allumage lequel allume •...
  • Page 36: Fonctionnement

    SUGGESTIONS POUR LE SERVICE ET L’ENTRETIEN. APPELER UN TECHNICIEN D’ENTRETIEN GÉNÉRAL: Tous les radiateurs ont reçu un test d’allumage pour vérifier le bon Ouvrir le robinet de gaz manuel et s’assurer qu’il n’y a pas de gaz allant à fonctionnement. Ceci inclus la flamme du brûleur principal, la flamme de la veilleuse, la veilleuse ou au brûleur principal.
  • Page 37 AVERTISSEMENT: Lors de l'entretien des commandes, tous les fils doivent être identifiés avant de les débrancher. Une erreur de filetage piut entraîner un mauvais et dangereux fonctionnement. Vérifier que le fonctionnement soit convenable après l'entretien. STAGE 1 TRIAL FOR IGNITION IF FLAME CURRENT SENSED *SPARK GENERATOR OFF *SECOND VALVE OPERATOR (MAIN) OPENS...
  • Page 38: Détection Des Défectuosités

    DÉTECTION DES DÉFECTUOSITÉS Important AVERTISSEMENT 1. Les procédures d’entretien suivantes sont fournies comme étant Lorsque vous exécutez les étapes suivantes, ne toucher pas à un guide général. l’extrémité dénudée du pont ou de la borne d’étincelle. Le circuit 2. Les lectures de compteu entre la commande de gaz et le d’allumage produit un courant électrique de 13,000 volts à...
  • Page 39 DÉP ART Note: A vant de détecter les défectuosités, familiarisez-vous avec la mise en marche et les procédures de vérification Fermer l'alimentation de gaz. Régler le contrôle our un appel de chaleur Vérifier le pouvoir de la ligne de tension, le transformateur à basse ten- Pouvoir du module sion, le contrôle de tolérance, et l'installation électrique.
  • Page 40 S’IL VOUS PLAÎT NOTER: Lorsque vous commandez les pièces, il est très important que le numéro de la pièce et la description coïncident. Numéro Numéro Numéro Numéro d’index de la pièce d’index de la pièce Description Description 11762 Dessus de la paroi extérieure l’ouverture d’allumage avec mica 632024 Fixation du moteur (exige quatre)
  • Page 41 37403-5-0620 Page 17...
  • Page 42: Maintenance Historique De L'appareil

    MAINTENANCE HISTORIQUE DE L’APPAREIL Date Nom du distributeur Nom du technicien de service Entretien effectué/notes Page 18 37403-5-0620...
  • Page 43 MAINTENANCE HISTORIQUE DE L’APPAREIL Date Nom du distributeur Nom du technicien de service Entretien effectué/notes 37403-5-0620 Page 19...
  • Page 44 Empire Comfort Systems Inc. Belleville, Illinois Pour toute question générale concernant nos produits, veuillez nous envoyer un courriel à info@empirecomfort.com. Pour toute question d’entretien ou de réparation, veuillez contacter votre revendeur. www.empirecomfort.com Page 20 37403-5-0620...

Ce manuel est également adapté pour:

Dvc55ipxnat-1

Table des Matières